4 - 1 8
l O p e r a t i o n
C o n t r o l F u n c t i o n D e s c r i p t i o n s
S c r e e n
SCREEN 26
SETBACK TEMPERATURE
ACT 140°F
SET 140°F
SCREEN 27
SETBACK RETURN TEMP
ACT 100°F
SET 140°F
SCREEN 28
SETBACK TEMP BAND
SET 20°F
SCREEN 29 (Regeneration Outlet
Temperature)
REGEN OUTLET TEMP
ACT 280
F u n c t i o n
This screen shows the setpoint the process
temperature will go to once the control
goes into setback. When the control is in
the setback mode, the LED on the dryer
display beside SETBACK will illuminate.
The actual temperature on the default
screen will still show the actual tempera-
ture measured at the hopper inlet. The set-
point shown on the default screen will still
show the original setpoint.
This screen shows the actual temperature
measured at the hopper outlet and the set-
point temperature for the air at the hopper
outlet that will initiate the control to go
into setback.
This shows how much lower the hopper
outlet temperature must drop from the
Setback Return Temperature setpoint
(screen 27) before the dryer control should
restore the original process setpoint.
This screen shows the actual temperature
measured at the regeneration outlet of the
desiccant wheel manifold.
( c o n t i n u e d )