  • Page 1 Operation Manual XACT COUNT...
  • Page 2: Table Of Contents

    Operation Manual XACT COUNT TABLE OF CONTENTS TABLE OF CONTENTS ............................... 2 Intented Use ................................3 Applications ................................3 Environmental Parameters ........................... 3 Installation and Operation ............................3 Connections ................................3 Installation and Flow direction ..........................3 Discharge Cycle Counter Operation ........................4 Digital Display ..............................
  • Page 3: Intented Use

    It requires no external power source. A digital readout displays the number of times a pump cycles. An Xact Count cycle counter consists of a valve housing, an internally located and magnetically integrated poppet, and a digital display.
  • Page 4: Discharge Cycle Counter Operation

    DISCHARGE CYCLE COUNTER OPERATION When a pneumatically operated pump such as the QED AutoPump® has filled, it triggers itself "On”. This allows air to flow to the pump until a certain volume of fluid has discharged. The air ingress and fluid discharge stop, the pump refills, then the cycle repeats.
  • Page 5: Assembly/Cleaning

    Operation Manual XACT COUNT ASSEMBLY/CLEANING PARTS LIST 42202 CYCLE COUNTER Figure 1: Exploded View of Cycle Counter (42202) Table 1: Parts list for 42202 Xact Count Item Part Number Description Quantity 42167 BODY VALVE CHECK 1 FPT 316SS LASER ENGRAVED...
  • Page 6: Parts List 42204 Upgrade Kit

    Operation Manual XACT COUNT PARTS LIST 42204 UPGRADE KIT Figure 2: Exploded View of Cycle Counter Upgrade Kit (42204) Table 2: Parts list for 42204 Xact Count Upgrade Kit Item Part Number Description Quantity 42199 POPPET MAGNETIC ASSEMBLY DISCHARGE CC 316SS...
  • Page 7: Cleaning

    XACT COUNT CLEANING The Xact Count may not count due to either the magnet shuttle or the spring hanging up inside the magnet housing. The counter components can be cleaned by washing the unit in warm water. A soft brush may be used to remove debris.
  • Page 8: Check Valve Upgrade Kit

    Grooved on valve body must be present for compatibility with upgrade kit (42204) Figure 4: Unit Disassembly for Cycle Counter Upgrade Note: Parts in grayline not included in Xact Count Upgrade Kit (42204) REV 00 PN: 95416 Page 8 of 12...
  • Page 9: Technical Specifications

    Operation Manual XACT COUNT TECHNICAL SPECIFICATIONS PATENT INFORMATION The equipment in this manual is protected under U.S. and foreign patents issued and pending. For a complete list of patents visit www.graco.com/patents. The equipment in this manual is protected under Registered Trademarks. For a complete list of Registered Trademarks and Trademarks, visit www.graco.com/trademarks.
  • Page 10: Warranty Information

    Chemical attack by liquids contacting equipment and accessories shall not be covered by this warranty. A range of materials of construction is available from QED and it is the buyer’s responsibility to select materials of construction to fit the buyer’s application. QED will only warrant that the supplied site...