2.24 RESTART PROCEDURE

Legend
A. Domestic Hot Water Temperature Knob
B. Central Heating Temperature Knob
C. Mode Knob
D. Boiler Status Display
E. Burner 'on' Indicator
F. Preheat On Off button
G. Restart button
H. Central Heating Economy Setting
J. Pressure Gauge

2.25 ACCESSING THE INSTALLER MODE

To access Installer Mode press the "PREHEAT" and "RESTART" Buttons
together for more than 5s.
1. The last 3 faults will be shown
See Section 4.1 for Fault Code descriptions
2. "SL" will be shown
To run the burner at minimum rate press "RESTART", otherwise
press "PREHEAT".
3. "SH" will be shown
To run the burner at maximum rate press "RESTART", otherwise
press "PREHEAT".
4. "VF" will be shown
To activate the venting function press "RESTART", otherwise press
"PREHEAT".
Installation and Servicing
SECTION 2 - INSTALLATION
To restart the boiler, press the RESTART button (G).
MIN
MAX
J
A
D
BOILER
e
ºC
HOT WATER
PREHEAT
ON
MIN
MAX
PREHEAT
RESTART
F
G
E
B
The venting function runs for 5 minutes before automatically
returning to normal operation
The diverter valve moves between CH and DHW every 30s
The Pump alternates between being on for 50s and then off for 10s
5. "dU" will be shown
To move the diverter valve to mid-position for replacement press
"RESTART", otherwise press Preheat
6. "P1" will be shown
To set the minimum CH pump speed to 100% press "RESTART",
otherwise press "PREHEAT".
7. "P7" will be shown
To set the minimum CH pump speed to 70% (default) press
"RESTART", otherwise press "PREHEAT" to Exit
OFF
MODE
H
C
37