1-23. HUMAN SENSOR (OPTION)
Auto saving operation
If no one enters the room during the set time (15, 30, 60, 90, 120, 180 minutes), the set
temperature will be automatically controlled.
(When someone comes back into the room, the human sensor will detect this, and automatically
revert to the original settings).
(Table 12)
Operation mode
Cool / Dry
Heat
Auto off operation
If no one enters the room during the set time (1 to 24 hours in 1 hour increments), the air
conditioner will automatically stop operation.
Example of sensitivity range
Operation details
(if there is no one in the room for a while)
The set temperature will be increased by
a maximum of approximately 2
The set temperature will be decreased by
a maximum of approximately 2
* High limit : 30
°C.
* Low limit : 16
°C.
Equal sensitivity
range of temperature
01-25
°C
°C
Ceiling height :
3.2m
Detecting position :
0.8m from floor surface