Adapting The Unit To The Heating Installation; Burner Anti-Cycling Time; Setting The Pump Output - Vaillant ecoFIT pure 825 Installation And Maintenance Instructions Manual

Hide thumbs Also See for ecoFIT pure 825:
Table of Contents

Advertisement

8 Adapting the unit to the heating installation

Status codes – Overview (→ Page 32)
If the product is working correctly, the display shows
S.14.
8
Adapting the unit to the heating
installation
You can reset/change the system parameters.
Overview of diagnostics codes (→ Page 29)
8.1

Burner anti-cycling time

To prevent frequent switching on and off of the burner and
thus prevent energy losses, an electronic restart lockout
is activated for a specific period each time the burner is
switched off. The burner anti-cycling time is only active for
the heating mode. Hot water handling mode during a burner
anti-cycling time does not affect the time function element.
8.1.1
Setting the burner anti-cycling time
1.
Navigate to diagnostics code D.002 in the installer level
and confirm by pressing
2.
Set the burner anti-cycling time and confirm by pressing
.
T
Set maximum burner anti-cycling time [min]
Flow
(tar-
get)
1
5
[°C]
30
2.0
4.0
35
2.0
4.0
40
2.0
3.5
45
2.0
3.0
50
2.0
3.0
55
2.0
2.5
60
2.0
2.0
65
2.0
1.5
70
2.0
1.5
75
2.0
1.0
Set maximum burner anti-cycling time
T
Flow
[min]
(target)
[°C]
35
40
30
29.0
33.0
35
25.5
29.5
40
22.5
26.0
45
19.5
22.5
50
16.5
18.5
55
13.5
15.0
60
10.5
11.5
65
7.0
8.0
70
4.0
4.5
75
1.0
1.0
20
.
10
15
20
25
30
8.5
12.5
16.5
20.5
25.0
7.5
11.0
15.0
18.5
22.0
6.5
10.0
13.0
16.5
19.5
6.0
8.5
11.5
14.0
17.0
5.0
7.5
9.5
12.0
14.0
4.5
6.0
8.0
10.0
11.5
3.5
5.0
6.0
7.5
9.0
2.5
3.5
4.5
5.5
6.5
2.0
2.5
2.5
3.0
3.5
1.0
1.0
1.0
1.0
1.0
45
50
55
60
37.0
41.0
45.0
49.5
33.0
36.5
40.5
44.0
29.0
32.0
35.5
38.5
25.0
27.5
30.5
33.0
21.0
23.5
25.5
28.0
17.0
19.0
20.5
22.5
13.0
14.5
15.5
17.0
9.0
10.0
11.0
11.5
5.0
5.5
6.0
6.5
1.0
1.0
1.0
1.0
8.1.2
Resetting the remaining burner anti-cycling
time
Press
.
8.2

Setting the pump output

The product is equipped with a speed-regulated high-effi-
ciency pump, which adjusts independently to the hydraulic
conditions of the heating installation.
If you have installed a low loss header in the heating install-
ation, you should switch off the speed regulation and set the
pump output to a fixed value.
If required, change the setting of the pump speed, which
depends on the operating mode, under diagnostics code
d.14.
Overview of diagnostics codes (→ Page 29)
8.2.1
Pump diagrams
25c:
B
350
300
250
200
150
100
50
0
0
200
400
600
A
Remaining feed head
[mbar]
B
Flow rate [l/h]
30c:
B
450
400
350
300
250
200
150
100
50
0
0
200
400
A
Remaining feed head
[mbar]
B
Flow rate [l/h]
35c:
Installation and maintenance instructions ecoFIT pure 0020230531_01
1
2
800
1000
1200
1
Max. PWM
2
Min. PWM
2
600
800
1000
1200
1
Max. PWM
2
Min. PWM
A
1
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecofit pure 835

Table of Contents