6 Operation

5.5.6
Connecting controllers to the electronic
system
1
Safety thermostat for
floor-standing heating
2
24 V controller
1.
Open the electronics box. (→ Page 13)
2.
Carry out the wiring. (→ Page 13)
3.
Connect the individual components depending on the
type of installation.
Conditions: If installing a multi-circuit controller.
Change the pump's operating mode d.18 from Eco (in-
termittently operating pump) to Comfort (continuously
operating pump).
Conditions: When connecting a controller (230 V).
L
Connect the controller to the main plug.
Remove the bridge from the plug 24V=RT.
Conditions: 230 V 3-wire connection
Ensure that the controller is designed for a maximum
rated current of 7 A.
Connect the controller to the main plug X1.
Terminal assignment: L ‑ line, N ‑ neutral conductor,
‑ earth
Draw the operator's attention to the fact that the follow-
ing features are present with this type of installation.
The frost protection function is deactivated. If the
product is installed in a room where there is a risk
of frost and it has not been protected by a room ther-
14
24 V
BUS
+
Burner
24V=
off
RT
BUS
1
2
3
X2
X41
X22
4
3
eBUS controller or radio
receiver unit
4
Outside temperature
sensor, wired
X1
N
RT
230V~
mostat, install an additional frost protection thermo-
stat.
The pump programmes are not active.
If the product is switched off, the display is switched
off.
Each time the unit is started, the fan runs for
20 seconds.
Residual heat in the heating return may result in the
product blocking the burner for 10 minutes.
4.
Close the electronics box.
6
Operation
6.1

Operating concept

The operating concept and the display and setting facilities
of the operator level are described in the operating instruc-
tions.
An overview of the display and setting options in the installer
level can be found in the section "Overview of the installer
level". (→ Page 14)
6.2

Installer level overview

Installation and maintenance instructions ecoFIT pure 0020230531_01
S.31
Code
D.---
PF
P.--
D F
--/--
DP

Hide quick links: