7.12

Checking leak-tightness

Check the gas pipe, the heating circuit and the hot water
circuit for leak-tightness.
Check that the air/flue pipe has been installed correctly.
Conditions: Room-sealed operation
Check whether the vacuum chamber has been sealed so
that it is leak-tight.
7.13

Checking the heating mode

1.
Activate the heating mode on the user interface.
2.
Turn all thermostatic radiator valves on the radiators
until they are fully open.
3.
Allow the product to operate for at least 15 minutes.
4.
Purge the heating installation.
5.
Call up the Live Monitor.
Menu → Live Monitor
Status codes – Overview (→ Page 31)
If the product is working correctly, the display shows
S.04.
8
Adapting the unit to the heating
installation
You can reset/change the system parameters using the fol-
lowing menu points:
Menu → Installer level → Start inst. assistant
You can restart and run through the installation assistant at
any time.
Menu → Installer level Appliance config.
You can set/change the most important system parameters
in the Appliance config. menu point.
Menu → Installer level Diagnostics menu
You can set/change additional system parameters in the
Diagnostics menu point.
You can find an overview of all the system parameters in the
"Installer level – Overview" table in the appendix.
Installer level – Overview (→ Page 25)
8.1

Burner anti-cycling time

To prevent frequent switching on and off of the burner and
thus prevent energy losses, an electronic restart lockout
is activated for a specific period each time the burner is
switched off. The burner anti-cycling time is only active for
the heating mode. Hot water handling mode during a burner
anti-cycling time does not affect the time function element.
8.1.1
Setting the burner anti-cycling time
Set the burner anti-cycling time via the diagnostics code.
Overview of diagnostics codes (→ Page 28)
0020238195_01 ecoTEC plus Installation and maintenance instructions

Adapting the unit to the heating installation 8

8.1.2
Resetting the remaining burner anti-cycling
time
Press and hold the fault clearance key for more than
three seconds.
9
Handing the product over to the
operator
When you have finished the installation, attach the sticker
supplied (in the operator's language) to the product
cover.
Explain to the operator how the safety devices work and
where they are located.
Inform the operator how to handle the product.
In particular, draw attention to the safety information
which the operator must follow.
Inform the operator of the necessity to have the product
maintained on a regular basis.
Instruct the operator about measures taken to ensure the
supply of combustion air and flue gas pipe.

10 Troubleshooting

10.1

Rectifying faults

If fault codes (F.XX) are present, refer to the table in the
appendix for advice or use the check programme(s).
Overview of fault codes
Installer level – Overview (→ Page 25)
If several faults occur at the same time, the display shows
the corresponding fault messages for two seconds each in
alternation.
Press and hold the fault clearance key for more than
three seconds.
If you are unable to clear the fault code and it reappears
despite several fault clearance attempts, contact cus-
tomer service.
10.2

Calling up the fault memory

The last 10 fault messages are stored in the fault memory.
Navigate to the Fault list menu.
The display shows the number of faults that have
occurred, the fault numbers and the corresponding
plain text display.
Press
is shown in the display.
or
to call up individual fault messages.
19