M Vision CINE 400-3D Service Manual page 14

Advertisement

01
Inlet NTC thermal sensor is over temperature
sensor is over temperature. Temp. is over spec. Check and
replace Inlet thermal sensor
03
Lamp 1 over temperature
replace Lamp1 thermal state
a). To wait the cooling Mode finished.
b). To check the thermal sensor if shorted.
07
Ballast 1 over
temperature–
replace Ballast thermal state
a). To check if all fans are working.
b). To wait the cooling Mode finished.
c). To read back the ballast temp through serial interface
(DB9 connector).
20
Fans initial error when system power
power on. Anyone fan could be error when power on. Thus,
check and replace error fan you find out.
Fan1 locked and Fan1 get error during projector
21
Fan1 locked
working. Check and replace fan 1
Fan2 locked and Fan2 get error during projector
22
Fan2 locked
working. Check and replace fan 2.
Fan3 locked and Fan3 get error during projector
23
Fan3 locked
working. Check and replace fan 3.
Fan4 locked and Fan4 get error during projector
24
Fan4 locked
working. Check and replace fan 4.
Fan5 locked and Fan5 get error during projector
25
Fan5
locked–
working. Check and replace fan 5.
Fan6 locked and Fan6 get error during projector
26
Fan6
locked–
working. Check and replace fan 6.
Fan7 locked and Fan7 get error during projector
27
Fan7
locked–
working. Check and replace fan 7.
Fan8 locked and Fan8 get error during projector
28
Fan8 locked
working. Check and replace fan 8.
Fan9 locked and Fan9 get error during projector
29
Fan9 locked
working. Check and replace fan 9.
40
Lamp ignited fail 3 times when system power
times when system power on. Check and replace ballast and
power board.
a). To check the ballast control cable between Ballast and
Inlet NTC thermal
Lamp over temperature. Check and
Ballast is over temperature. Check and
Fans error when system
on–
on–
Lamp ignited fail 3