2. Error Code & Troubleshooting
2-1. HTD-8650 QDPAA/AB/AC Error Code
01
OverTempInlet–
Temp. is over spec. Check and replace Inlet thermal sensor
02
OverTempDMD
Temp. is over spec. Check and replace DMD thermal sensor
07
OverTempBallast1–
replace Ballast thermal state
(DB9 connector).
20
FanInitError–
could be error when power on. Thus, check and replace error
fan you find out.
21
Fan1RatateError
working. Check and replace fan 1
Inlet NTC thermal sensor is over temperature.
DMD NTC thermal sensor is over temperature.
Ballast is over temperature. Check and
a). To check if all fans are working.
b). To wait the cooling Mode finished.
c). To read back the ballast temp through serial interface
Fans error when system power on. Anyone fan
Fan1 locked, Fan1 get error during projector