Sanyo PLC-XC10 Service Manual page 37

Hide thumbs Also See for PLC-XC10:
Table of Contents

Advertisement

Electrical Adjustments
No.
Adjustment Item
9
FAN_1_SPEED_MONI
10
FAN_2_SPEED_MONI
11
FAN_3_SPEED_MONI
12
FAN_TEMP_A_MONI
13
FAN_TEMP_B_MONI
14
FAN_TEMP_C_MONI
15
16
TEMP_UPWARNING_TIME
17
NOR_TEMP_FAN1_MIN
18
NOR_TEMP_FAN1_MAX
19
NOR_TEMP_FAN2_MIN
20
NOR_TEMP_FAN2_MAX
21
NOR_WATT_FAN3_MIN
22
NOR_WATT_FAN3_MAX
23
NOR_VALU_FAN1_MIN
24
NOR_VALU_FAN1_MAX
25
NOR_VALU_FAN2_MIN
26
NOR_VALU_FAN2_MAX
27
NOR_VALU_FAN3_MIN
28
NOR_VALU_FAN3_MAX
29
ECO_TEMP_FAN1_MIN
30
ECO_TEMP_FAN1_MAX
31
ECOTEMP_FAN2_MIN
32
ECO_TEMP_FAN2_MAX
33
ECO_WATT_FAN3_MIN
34
ECO_WATT_FAN3_MAX
35
ECO_VALU_FAN1_MIN
36
ECO_VALU_FAN1_MAX
37
ECO_VALU_FAN2_MIN
38
ECO_VALU_FAN2_MAX
39
ECO_VALU_FAN3_MIN
40
ECO_VALU_FAN3_MAX
41
HINOR_TEMP_FAN1_MIN
42
HINOR_TEMP_FAN1_MAX
43
HINOR_TEMP_FAN2_MIN
44
HINOR_TEMP_FAN2_MAX
45
HINOR_WATT_FAN3_MIN
46
HINOR_WATT_FAN3_MAX
47
HINOR_VALU_FAN1_MIN
48
HINOR_VALU_FAN1_MAX
49
HINOR_VALU_FAN2_MIN
50
HINOR_VALU_FAN2_MAX
51
HINOR_VALU_FAN3_MIN
52
HINOR_VALU_FAN3_MAX
53
HIECO_TEMP_FAN1_MIN
54
HIECO_TEMP_FAN1_MAX
55
HIECOTEMP_FAN2_MIN
56
HIECO_TEMP_FAN2_MAX
57
HIECO_WATT_FAN3_MIN
58
HIECO_WATT_FAN3_MAX
59
HIECO_VALU_FAN1_MIN
60
HIECO_VALU_FAN1_MAX
61
HIECO_VALU_FAN2_MIN
62
HIECO_VALU_FAN2_MAX
63
HIECO_VALU_FAN3_MIN
64
HIECO_VALU_FAN3_MAX
65
CLNOR_TEMP_FAN1_MIN
66
ClNOR_TEMP_FAN1_MAX
67
CLNOR_TEMP_FAN2_MIN
68
CLNOR_TEMP_FAN2_MAX
69
CLNOR_WATT_FAN3_MIN
70
CLNOR_WATT_FAN3_MAX
71
CLNOR_VALU_FAN1_MIN
72
CLNOR_VALU_FAN1_MAX
73
CLNOR_VALU_FAN2_MIN
74
CLNOR_VALU_FAN2_MAX
75
CLNOR_VALU_FAN3_MIN
76
CLNOR_VALU_FAN3_MAX
77
CLECO_TEMP_FAN1_MIN
78
CLECO_TEMP_FAN1_MAX
79
CLECOTEMP_FAN2_MIN
80
CLECO_TEMP_FAN2_MAX
81
CLECO_WATT_FAN3_MIN
82
CLECO_WATT_FAN3_MAX
83
CLECO_VALU_FAN1_MIN
84
CLECO_VALU_FAN1_MAX
85
CLECO_VALU_FAN2_MIN
86
CLECO_VALU_FAN2_MAX
87
CLECO_VALU_FAN3_MIN
88
CLECO_VALU_FAN3_MAX
89
FAN1_ADJUST_VOLT_MIN
90
FAN1_ADJUST_VOLT_MAX
91
FAN2_ADJUST_VOLT_MIN
92
FAN2_ADJUST_VOLT_MAX
Initial Value
Range
Input source / Description
-
0 ~ 255
Fan Speed Monitor when FAN_CONTROL_SW is set to 0, Read only
-
0 ~ 255
-
0 ~ 255
-
-
Read only
-
-
-
-
3
0 ~ 5
Set +20 degree to Temp Error value while X min. rom startup.
31
FAN1 control start temp. at Normal
39
FAN1 control stop temp. at Normal
31
0~255
FAN2 control start temp. at Normal
39
FAN2 control stop temp. at Normal
24
FAN3 control start wattage (x10) at Normal
30
FAN3 control stop wattage (x10) at Normal
85
FAN1 control Min value at Normal(0:Fan voltage 0VÅA255:Fan voltage 25.5V)
135
FAN1control Max value at Normal
90
0~255
FAN2 control Min value at Normal
135
FAN2 control Max value at Normal
65
FAN3 control Min value at Normal
100
FAN3 control Max value at Normal
31
FAN1 control start temp. at Eco
39
FAN1 control stop temp. at Eco
31
0~255
FAN2 control start temp. at Eco
39
FAN2 control stop temp. at Eco
24
FAN3 control start wattage (x10) at Eco
30
FAN3 control stop wattage (x10) at Eco
75
FAN1 control Min value at Eco
125
FAN1control Max value at Eco
80
0~255
FAN2 control Min value at Eco
125
FAN2 control Max value at Eco
65
FAN3 control Min value at Eco
100
FAN3 control Max value at Eco
22
FAN1 control start temp. at Highland Normal
32
FAN1 control stop temp. at HighlandNormal
22
0~255
FAN2 control start temp. at HighlandNormal
32
FAN2 control stop temp. at HighlandNormal
24
FAN3 control start wattage (x10) at HighlandNormal
30
FAN3 control stop wattage (x10) at HighlandNormal
85
FAN1 control Min value at Highland Normal(0:Fan voltage 0VÅA255:Fan voltage 25.5V)
135
FAN1control Max value at Highland Normal
90
0~255
FAN2 control Min value at Highland Normal
135
FAN2 control Max value at Highland Normal
85
FAN3 control Min value at Highland Normal
120
FAN3 control Max value at Highland Normal
22
FAN1 control start temp. at Highland Eco
32
FAN1 control stop temp. at Highland Eco
22
0~255
FAN2 control start temp. at Highland Eco
32
FAN2 control stop temp. at Highland Eco
24
FAN3 control start wattage (x10) at Highland Eco
30
FAN3 control stop wattage (x10) at Highland Eco
75
FAN1 control Min value at Highland Eco
125
FAN1control Max value at Highland Eco
80
0~255
FAN2 control Min value at Highland Eco
125
FAN2 control Max value at Highland Eco
85
FAN3 control Min value at Highland Eco
120
FAN3 control Max value at Highland Eco
31
FAN1 control start temp. at Ceiling Normal
39
FAN1 control stop temp. at CeilingNormal
31
0~255
FAN2 control start temp. at CeilingNormal
39
FAN2 control stop temp. at CeilingNormal
24
FAN3 control start wattage (x10) at CeilingNormal
30
FAN3 control stop wattage (x10) at CeilingNormal
85
FAN1 control Min value at Ceiling Normal(0:Fan voltage 0VÅA255:Fan voltage 25.5V)
135
FAN1control Max value at Ceiling Normal
90
0~255
FAN2 control Min value at Ceiling Normal
135
FAN2 control Max value at Ceiling Normal
65
FAN3 control Min value at Ceiling Normal
100
FAN3 control Max value at Ceiling Normal
31
FAN1 control start temp. at Ceiling Eco
39
FAN1 control stop temp. at Ceiling Eco
24
0~255
FAN2 control start temp. at Ceiling Eco
39
FAN2 control stop temp. at Ceiling Eco
24
FAN3 control start wattage (x10) at Ceiling Eco
30
FAN3 control stop wattage (x10) at Ceiling Eco
75
FAN1 control Min value at Ceiling Eco
125
FAN1control Max value at Ceiling Eco
80
0~255
FAN2 control Min value at Ceiling Eco
125
FAN2 control Max value at Ceiling Eco
65
FAN3 control Min value at Ceiling Eco
100
FAN3 control Max value at Ceiling Eco
35
DAC adjustment value for FAN1MIN(4.5V)
231
DAC adjustment value for FAN1MAX(13.8V)
37
0~255
DAC adjustment value for FAN2 MIN(4.5V)
232
DAC adjustment value for FAN2 MAX(13.8V)
-37-
* Fan Voltage Adjustment
* Fan Voltage Adjustment
* Fan Voltage Adjustment
* Fan Voltage Adjustment

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-sc10Plc-xu60Plc-su60