■ Optical Adjustments

Before taking optical adjustments below, remove the Cabinet Top following to the "Mechanical Disassemblies".
Adjustments require a 2.0mm hex wrench and a slot screwdriver. When you adjust Integrator lens, Relay lens or
Mirror adjustment, you need to disconnect FPC cables of LCD panels on the main board.
Note: Do not disconnect connectors on the main board, because the projector cannot turn on due to operate the
power failure protection.
When the cabinet top or lamp cover is removed, the lamp cover switch is turned off. When turning on the pro-
jector for servicing or adjusting, it is required to keep turning on the lamp cover switch.
Contrast adjustment
[Before Adjustment]
- Input a 100% of black raster signal.
1
A
Loosen a screw
(Fig.1-1/1-2) on the polarized glass mounting
base which you intend to adjust.
2
Turn the polarized glass mounting base as shown in Fig.1-1 to
obtain the darkest brightness on the screen.
3
A
Tighten the screw
to fix the polarized glass mounting base.
Repeat steps 1 to 3 for remaining polarized glasses.
Polarized
mounting base
A
B-Polarized Glass
Mounting Base
-21-