This document explains how to connect to the NI 9203. In this document, the NI 9203 with screw-terminal and the NI 9203 with spring-terminal are referred to inclusively as the NI 9203. Before you begin, complete the software and Note hardware installation procedures in your chassis documentation.
Page 5
Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Do not connect the NI 9203 to signals or use Caution for measurements within Measurement Categories II, III, or IV.
Safety Guidelines for Hazardous Locations The NI 9203 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous locations only.
Page 7
II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9203 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. 8 | ni.com | NI 9203 Getting Started Guide...
Preparing the Environment Ensure that the environment in which you are using the NI 9203 meets the following specifications............Operating temperature -40 °C to 70 °C (IEC 60068-2-1, IEC 60068-2-2) ............Operating humidity 10% RH to 90% RH, (IEC 60068-2-78) noncondensing ............
Page 11
Figure 1. NI 9203 Pinout Each channel has an AI terminal to which you can connect a current signal. The NI 9203 also has a common terminal, COM, that is internally connected to the isolated ground reference of the module.
NI 9203 Datasheet NI 9203 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION C Series Documentation Services & Resources ni.com/services cseriesdoc ni.com/info Located at ni.com/manuals Installs with the software 12 | ni.com | NI 9203 Getting Started Guide...
Page 15
National Instruments Patent Notice at patents . You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.