ADJUSTING PRESET FILTER CYCLES
Filter duration is programmable between 0.5 and 6 hours in 30 minute increments (0.5 hours) for
both filter cycles. To program the cycle times:
1. Press and hold Light button for 5+ seconds until F1 is displayed.
2. Press the Plus or Minus button to adjust the cycle time for F1.
3. Press the Light button to store the F1 cycle and move to the F2 cycle.
4. Press the Plus or Minus button to adjust the cycle time for F2.
5. Wait 15 seconds to allow the exit timer to expire and store the setting.
IMPORTANT: To reset the first filter cycle start time, skip step 5 and continue pressing the Light
button until the actual temperature is displayed. Powering down of the spa will also reset the first
filter start time.
FILTER CYCLE SUSPENSION:
light is activated manually during the filter cycle time. The suspension will end around 15 minutes
after the completion of the manual use.
FAHRENHEIT/CELSIUS SETTING:
To change water temperature display to either Fahrenheit or Celsius, press and
hold Light button for 5+ seconds until F1 is displayed. Press the Light button
several times until F or C
change. Wait 15 seconds to allow the exit timer to expire and store the setting.
ECONOMY MODE:
This mode allows you to lower the temperature set point of the spa by 20°F
(11°C), to change to the Economy mode press and hold Light button for 5+
seconds until F1 is displayed. Press the Light button several times until the
display shows EP 1, use Down key to disable economy mode, the display will
show EP 0. Wait 15 seconds to allow the exit timer to expire and store the setting.

OPERATIONAL MODES

The Standard Mode is the default operational mode preset from the factory. In order to program the
spa to operate in the Economy mode you must enter the programming mode to make the change.
Water sampling will turn the jet pump on and circulate the water for up to a couple of minutes.
NOTE: Freeze Protection (Smart Winter Mode) will assert as necessary during all modes.
STANDARD MODE:
circulation (sampling) to sample and heat the water to the set temperature.
ECONOMY MODE:
SLEEP MODE:
The spa will only heat during the filter cycles. Water sampling only done during the filter
cycle.
QUIET MODE:
Keeps the jet pump from running (water sampling) after the F2 filter cycle is complete for
up to 11.5 hours. You can set this mode between 0.5 hours and 11.5 hours in half hour increments.
To enter the programming screen and toggle between Standard, Economy, Sleep and Quiet
Modes the following is required:
CONTROL PANEL OPERATION
The filter cycle will be suspended every time a jet pump or
is displayed. Press the Plus or Minus button to
(2 pump models only)
(1 pump models only)
Is programmed to maintain the desired temperature with periodic water
The spa will not heat. Water sampling only done during the filter cycle.