Intake/Exhaust Manifold Removal And Vent Installation - Vermont Castings ICFDV Series Installation And Operating Instructions Manual

Direct vent gas fireplace insert
Table of Contents

Advertisement

VENTING INSTALLATION
INTAKE/EXHAUST MANIFOLD REMOVAL
AND VENT INSTALLATION
The intake/exhaust manifold is shipped attached to insert.
It may be removed to allow tight installation.
1. Unfasten the two (2) machine screws on the face of the
unit and release the plate assembly by sliding the plate
back.
2. Attach the exhaust and the intake flex pipes to the collar
on the plates with a hose clamp (not provided) or other
approved methods (check local codes).
3. Re-attach exhaust baffle and manifold assembly in
reverse order of Step 1.
Exhaust Collar
Machine
Screws
Figure 10
4. While sliding unit in place, if necessary the glass latch/
shutoff tool can be used to help place the plate assem-
bly. Using the small end of the tool, insert it in the square
notch in top front of firebox. Hook the plate assembly
with tool and pull forward into place while sliding firebox
to the rear. Figure 11
5. Reinstall and tighten machine screws.
20306752
Plate
Assembly
Intake Collar
Figure 11
Exhaust/Intake
Slide Plate
Assembly
The unit is shipped from the factory as a natural gas unit
with the baffle installed. The baffle should be sufficient for
venting up to 20 feet (6 m) off the top of the unit. An extra
baffle plate is shipped with the unit for installations 20
feet and above. Adjust the plate to the closed position as
desired. Figure 12
FP2979
Figure 12 -
Baffle Assembly and Adjustment
Latch Tool
FP2977
latch tool plate assy
Loosen Four (4) Screws to Adjust
Bottom View
Closed Position
FP1961
baffle adjustment
9/08
ICFDV30 Fireplace Insert
FP2977
Bottom View
Open Position
13