Technical Data; Electrical Data - Riello RS 1000/E BLU Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

4.3

Technical data

Model
Type
Output
(1)
Output
(1)
Fuels
Gas pressure at max. output
Gas: G20/G25
Operation
Standard applications
Ambient temperature
Combustion air temperature
Noise levels
Sound pressure
(3)
Sound power
Weight
Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Pressure on the socket 5) (Fig. 4) with zero pressure in the combustion chamber and at maximum burner output.
(2)
Noise emission tests carried out as per Directive EN 15036-1, with measurement accuracy σ = ± 1.5 dB, in the manufacturer's combustion lab with
(3)
burner operating on test boiler at maximum output.
4.4

Electrical data

Model
Electrical supply
Fan motor IE2
Ignition transformer
Absorbed electrical power
Protection level
Model
Electrical supply
Fan motor IE3
Ignition transformer
Absorbed electrical power
Protection level
20058360
Technical description of the burner
min - max
kW
-
(2)
mbar
°C
°C max
dB(A)
Kg
rpm
Hz
V
kW
A
V1 - V2
I1 - I2
kW max
rpm
Hz
V
kW
A
V1 - V2
I1 - I2
kW max
RS 1000/E BLU
1133 T1
1100/4000 - 10100
Natural gas: G20 (methane gas) - G21 - G22 - G23 - G25
64.5/92.7
Intermittent (min. 1 stop in 24 hours)
Modulating
Boilers: water, steam, diathermic oil
85
99
460
RS 1000/E BLU
3N ~ 400V +/-10% 50 Hz
2935
50
400/690
22
38.6/22.3
24
RS 1000/E BLU
3N ~ 400V +/-10% 50 Hz
2880
50
400/690
22
38.2/22.3
24
8
GB
RS 1200/E BLU
1134 T1
1500/5500 - 11100
80.5/114
0 - 50
60
89.3
99.7
500
RS 1200/E BLU
2920
50
400/690
25
44.1/25.5
230 V - 2 x 5 kV
1.9 A - 35 mA
27
IP 55
RS 1200/E BLU
2880
50
400/690
25
43.4/25.1
230 V - 2 x 5 kV
1,9 A - 35 mA
27.2
IP 55
Tab. B
Tab. C
Tab. D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs 1200/e blu1133 t11134 t1

Table of Contents