Haier AS09TA2HRA Service Manual page 23

Wall mounted type dc inverter
Hide thumbs Also See for AS09TA2HRA:
Table of Contents

Advertisement

Temp.( )
Resistor K
-20
266.905
-19
250.866
-18
235.895
-17
221.911
-16
208.838
-15
196.609
-14
185.163
-13
174.443
-12
164.399
-11
154.983
-10
146.153
-9
137.87
-8
130.096
-7
122.799
-6
115.946
-5
109.51
-4
103.462
-3
97.779
-2
92.437
-1
87.415
0
82.691
1
78.248
2
74.067
3
70.133
4
66.43
5
62.943
6
59.659
7
56.566
8
53.651
9
50.904
10
48.314
11
45.872
12
43.569
13
41.395
14
39.343
15
37.406
16
35.577
17
33.848
R25
Temp.
Resistor K
18
32.215
19
30.671
20
29.21
21
27.828
22
26.521
23
25.283
24
24.111
25
26
21.94
27
20.94
28
19.99
29
19.09
30
18.23
31
17.42
32
16.65
33
15.97
34
15.22
35
14.56
36
13.93
37
13.34
38
12.77
39
12.23
40
11.71
41
11.22
42
10.76
43
10.31
44
9.89
45
9.49
46
47
8.74
48
8.39
49
8.05
50
7.73
51
7.43
52
7.14
53
6.86
54
55
6.34
21
Functions and control
Temp.
56
57
58
59
60
61
62
23
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
8.1
6.6
Domestic air conditioner
Resistor K
6.1
5.87
5.65
5.44
5.24
5.04
4.86
4.68
4.51
4.35
4.19
4.04
3.9
3.76
3.63
3.5
3.38
3.26
3.15
3.04
2.94
2.84
2.74
2.65
2.56

Hide quick links: