User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
REQUIREMENTS
Compressed air requirements
Water requirements
Liquid temperature range
Electrical requirements
Operating voltage
Chemical compatibility

SPECIFICATIONS

Power type
Chemical pickup type
Dilution ratio range
(water:chemical)*
Number of products unit can
draw from (and whether it draws
simultaneously or one at a time)
Suction line length/diameter
Flow rate*
Pump seals
Timer operation type
Coverage area
Fan tip
Nozzle type
Number of nozzles
Distance from nozzles to control
box
Tubing/fitting sizes
*Dilution rates and flow rates given are based on chemical with viscosity of water and factory air pressure settings.
Model No.: DS4, DS4K, DS4V
40-80 psi (3-5 bar) with 5-10 cfm (141.6-283.3 l/min)
10-100 psi (0.69-6.9 bar)
Backflow prevention is required – consult local plumbing ordinances for more information.
40-100˚F (4.4-37˚C)
120 VAC at 60 Hz, 2 amps (GFCI protected outlet)
120 VAC
Chemical products used with this equipment must be formulated for this type of application
and compatible with unit materials and pump seals. For more information on chemical
compatibility, consult the manufacturer or SDS for your product or contact our customer
service department.
Compressed air, electricity
Draws from concentrated product
38:1 to 183:1
One product
8 ft. (2.4 m) clear hose with 1/4 in. (6.4 mm) inside diameter
2 gal/min (7.6 l/min)
Santoprene, Viton, or Kalrez
Repeat cycle
With one nozzle: up to 9x5 ft. (2.7x1.5 m);
With two nozzles: up to 8x4 ft. (2.4x1.2 m) at each nozzle;
With three nozzles: up to 6x3 ft. (1.8x0.9 m) at each nozzle
With one nozzle: ST80200SS;
With two nozzles: ST80100SS;
With three nozzles: ST8060-12SS
Twin-line stainless steel nozzle assembly (GK7T)
One control box can support up to three nozzle assemblies
The combined distance between the control box and the nozzle(s) must equal 100 ft. (30.5 m)
or less.
Designed for use with 1/2 in. (12.7 mm) outside diameter tubing between control box and
nozzle(s)
Page 4 of 10 | 20180404