Tank Draining - ICE COBOTICS i-SYNERGY i28BTL+ Operator's & Parts Manual

Automatic scrubber
Table of Contents

Advertisement

6. When the solution tank runs empty, press the
1-Step switch raise the brush head. Keep the
squeegee down and continue to vacuum until all
the dirty water is picked up.
NOTE: Brush motors will not work when
the scrub head assembly raised.
NOTE: See TANK DRAINING section to learn
how to drain recovery and solution tanks.
CIRCUIT BREAKER / FUSES
The machine is equipped with 2 resettable circuit
breakers(machine components, item #5, item#
6) to protect the main controller from damage. If
the circuit breakers should trip, it can't be reset
immediately. You must first determine what caused
the breaker to trip, and allow the motor to cool
down and then you can manually reset the circuit
breakers.
The machine is also equipped with a 150A fuse
to protect the Lithium-ion batteries from damage.
When replacing a fuse never substitute a higher
Amps rated fuse than specified.
HOUR METER
The hour meter (Panel machine components, item
#17) records the number of total hours the brush
motor has been powered on. Use the hour meter
to determine when to perform recommended
maintenance procedures and to record service
history.
EMERGENCY STOP BUTTON/ BRAKE
The machine is equipped with an Electromagnetic
Brake Mechanism on the Transaxle. When in
case of Emergency, release the Control Handle
bail or strike the Emergency stop button (Machine
components, item #4), the machine will be braked
and then stop. Reset the emergency stop button,
turn on the machine, and then pull the control
handle bail, the machine will be restart.
NOTE: The machine can not be moved unless the
Main Power and the Control Handle bail be turned
on.
WARNING: Do Not Change the Default
Settings of the Electromagnetic Brake
Mechanism unless Authorized, otherwise it
may cause Machine Damage or Personal Injury.
Contact the Authorized Service center for
machine repairs.
ICE i28BTL / i28BTL-CY / i32BTL
OPERATOR MANUAL

TANK DRAINING

1. Turn the machine off.
2. With the squeegee and scrub head in their "up"
position, transport machine to approved area for
draining tank(s).
DRAINING THE RECOVERY TANK
Any time scrubbing is completed, or when refilling
solution tank, the recovery tank should be drained
and cleaned.
WARNING: If the recovery tank is not
drained when the solution tank has been
refilled, foam or water may enter the float shut-
off screen and cause damage to the vacuum
motor.
1. While holding the drain hose (Machine
components, item #3) upward, remove the cap
and lower hose to drain.
2. Open the recovery tank cover and rinse out the
tank. Use a rag to remove any excess dirt.
3. Clean the float shut-off screen and debris tray
located in the recovery tank .
DRAINING THE SOLUTION TANK
Any time scrubbing operation is completed, the
solution tank should be drained and cleaned.
1. Pull the solution tank level hose(Machine
components, item #12) off the hose fitting, this
will allow the solution to flow freely into a bucket
or floor drain.
2. Remove the cover of the filter assembly
(Machine components, item #10) to drain the
solution tank, check the filter screen and clean
up it if necessary.
3. Rinse the solution tank with clean water after
every use. This will help prevent chemical
buildup and clogging of the solution lines.
4. After rinsing out the tank, securely reconnect
the tank level hose to the hose fitting, replace
the filter assembly cover and be sure the
filter screen and the "O" ring is in the correct
position.
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

I-synergy i28btl+-cyI-synergy i32btl+

Table of Contents