Fault Code & Solution - ICE COBOTICS i-SYNERGY i28BTL+ Operator's & Parts Manual

Automatic scrubber
Table of Contents

Advertisement

OPERATOR MANUAL
The machine is equipped with a LED display screen
(Panel components, item # 4), the LED screen will
display the operating hours (Panel components,
item # 17) and the battery level status (see Panel
components, item # 2).
When the machine detects a fault, there will be a
Fault code (Panel components, item #18) & Fault
message (Panel components, item #11) display
on the LED screen, and the Fault indicator (Panel
components, item #1) will flash continuously,
accompany an audible alarm Occasionally.
FAULT
FAULT MESSAGE
CODE
Bru Actt O.L.
F03
RESTART!
Vac Mtr O.L.
F04
RE-START!
Left Bru Mtr O.L.
F05
RE-START!
Right Bru Mtr O.L.
F06
RE-START!
Propel Mtr O.L.
F07
RE-START!
F08
RecTank Full
Batt Low
F10
Charge Batt
Batt Empty
F11
Charge Batt NOW
F12
Brake Wiring Error
F14
Replace Brake Assy
Control Unit Overheat!
F16
Wait
F17
Replace Control Unit
F20
Check Left Brush motor
F21
Check Vac Mtr
F22
Check Soln Solenoid
F23
Replace Soln solenoid
F24
Check Propel Motor
F25
Check Right Brush motor
F40
Check Proximity Sw
F41
Release Handle
F42
Replace Control Unit
Turn Dead Sw Off
F43
RE-START!
F44
Replace Control Unit
F45
Return Control Unit
F46
Return Control Unit
F47
Return Control Unit
F48
Return Control Unit
14
FAULT CODE & SOLUTION
Once fault occuring, please DO NOT continue
operate the machine unless the fault are eliminated.
Turn off the machine, then to solve the fault, the
fault code & message will be eliminated when
machine restart.
If the fault is occurred frequently, or the fault can't
be eliminated, please contact ICE service center.
Please refer to the below table to determine the
fault cause and the solution.
FAULT CAUSE
Scrub head lifting actuator is overload
Vacuum motor overload
Left brush motor is overload
Right brush motor is overload
Propel motor overload
Recovery tank is full
Battery is low
Battery is empty
Bad Brake wiring
Bad Brake assembly
Control Unit Overheat
Control Unit Fault
Bad left brush motor
Bad Vacuum motor or wiring
Solution solenoid wiring fault
Bad Solution solenoid
Bad propel motor
Bad right brush motor
Proximity switch fault
Operation mistake
Bad Control Unit
Emergency stop button activated
Bad Control Unit
SOLUTION
Turn off the machine,after a moment,
RE-START machine.
Drain the Recovery tank
Charge the battery
Charge the battery NOW
Check the brake wiring
Replace the brake assembly
Turn off the machine,after a moment,
RE-START machine
Replace the control unit
Check left brush motor/ wiring
Check the vacuum motor / Wiring
Check the wiring & Contactors
Replace the solution solenoid
Check the propel motor / Wiring
Check right brush motor/ wiring
Check the Proximity switch
Release the control handle bail
Replace the control unit
Release emergency stop button and
restart machine
Contact service center, Replace the
Control Unit
ICE i28BTL / i28BTL-CY / i32BTL

Advertisement

Table of Contents
loading

This manual is also suitable for:

I-synergy i28btl+-cyI-synergy i32btl+

Table of Contents