Download Print this page
Loreme ANL201 Configuration Handbook

Loreme ANL201 Configuration Handbook

Field mount numeric display ethernet link

Advertisement

Quick Links

Field mount numeric display
Ethernet link
CONFIGURATION HANDBOOK
ANL201
LOREME 12, rue des Potiers d'Etain Actipole BORNY - B.P. 35014 - 57071 METZ CEDEX 3
Phone 03.87.76.32.51
Contact : Commercial@Loreme.fr - Technique@Loreme.fr
Download manual at : www.loreme.fr
REV 0 14/12/10
E 1

Advertisement

loading

Summary of Contents for Loreme ANL201

  • Page 1 Field mount numeric display Ethernet link CONFIGURATION HANDBOOK ANL201 LOREME 12, rue des Potiers d'Etain Actipole BORNY - B.P. 35014 - 57071 METZ CEDEX 3 Phone 03.87.76.32.51 Contact : Commercial@Loreme.fr - Technique@Loreme.fr Download manual at : www.loreme.fr REV 0 14/12/10...
  • Page 2: Table Of Contents

    2) Recommendations of use ........................p6 2.1) General remarks .......................... p6 2.2) Power supply ..........................p6 2.3) Input / output ..........................p6 WIRINGS ................................p7 LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 3: Device Presentation

     TABLE OF CONTENTS Device Presentation The ANL201 is an indicator driven with the Ethernet link on Modbus TCP. This device was designed for use in harsh environment (outdoor) or in explosive environment . Description of Display: Power supply connector (under the front face) ...
  • Page 4 ‘ ’. The limits for the timeout delay are : 1sec to 60sec. The ANL201 display a series of 5 dashes during the storage of the new parameters. End of configuration. LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 5: Modbus Tcp Communication

    4) Communication To display a value in ANL201, the master should send a writing request to the registers at address 0000 and 0001. The function code for this request can be 06 (for 2 writing) or 16 (for 1 writing).
  • Page 6: Emc Consideration

    1) Introduction To meet its policy concerning EMC, based on the Community directives 2014/30/EU & 2014/35/EU, the LOREME company takes into account the standards relative to this directives from the very start of the con- ception of each product. The set of tests performed on the devices, designed to work in an industrial environment, are made in accor- dance with IEC 61000-6-4 and IEC 61000-6-2 standards in order to establish the EU declaration of confor- mity.
  • Page 7: Wirings

     TABLE OF CONTENTS Wirings Power supply connection. (ANL201 without front face) pluggable power supply terminal block Ethernet cord Outline dimensions ...