PS-HL-138xxBM Series : 13.8V dc Switch Mode Power Supplies
with Standby battery charging, fault monitoring & remote fault signalling
PS-HL-13805BM-4OP (5A / 4 x Fused Outputs)
F
EATURES
High efficiency cost effective power supply range ideal for Access Control applications.
Featuring a regulated 13.8V dc output supplying continuous full rated current to load
and a universal mains voltage input. Standby battery recharging is achieved within 24h
for an 18Ah battery. Maximum battery life is assured using deep discharge protection
to prevent premature battery failure when operating in standby mode for extended
periods. Two sets of volt free contacts are provided to signal (i) loss of mains and (ii)
battery and loss of output faults. The 5A model is provided with 4 x 1.25A Fused
Outputs whilst the 10A model is provided with 8 x 1.25A Fused Outputs.
Continuous full rated current to load
18Ah Standby battery recharged to 80% within 24 hours
Universal mains input voltage 90-264V ac
High efficiency electronics for reduced running costs and lower operating
temperatures
Installer safe design with all high voltage electronics fully shrouded
Full electronic short circuit and overload protection on load output under mains
operation
Mains transient protection circuit
Lid and removal from wall tamper detection
Green Mains present LED
Red Fault LED
Volt free contact signalling mains failure
Volt free contact signalling output and battery faults
Individually Fused Outputs
Tel:
:
www.honeywell.com
PS-HL-13810BM-8OP (10A / 8 x Fused Outputs)
PAK200467-HW_01A March 2020
+971 4 450 5800
1
2020 Honeywell Security

Advertisement

loading

Summary of Contents for Honeywell PS-HL-138 BM Series

  • Page 1 Honeywell Middle East Emaar business Park, Tel: +971 4 450 5800  www.honeywell.com PS-HL-138xxBM Series : 13.8V dc Switch Mode Power Supplies with Standby battery charging, fault monitoring & remote fault signalling PS-HL-13805BM-4OP (5A / 4 x Fused Outputs) PS-HL-13810BM-8OP (10A / 8 x Fused Outputs) EATURES High efficiency cost effective power supply range ideal for Access Control applications.
  • Page 2: Specification

    (mm) [external] 1 x NP17 (18Ah) 2 x NP17 (18Ah) Max Battery Capacity Weight (kg) excluding 5.42 battery Environmental Temperature -10 to +40°C (operating) 95% RH non-condensing -20 to +80°C (storage) PAK200467-HW_01A March 2020 2020 Honeywell Security...
  • Page 3: Local Indicators

    *For 10A model, only one Fault LED will be visible via front panel. Each module has independent fault monitoring and signalling. PAK200467-HW_01A March 2020 2020 Honeywell Security...
  • Page 4 Rating: 0.1A @ 60V dc N/O volt free contact. Lid Tamper Note: Contact open in when lid opened by normal means or unit is removed from mounted surface Rating: 3A @ 125V ac N/O volt free contact. PAK200467-HW_01A March 2020 2020 Honeywell Security...
  • Page 5: Installation And Commissioning

    10) Verify load is operating correctly. 11) Disconnect mains power. Standby Battery 12) Attach supplied battery cables to terminal block and battery. NOTE: ensure correct polarity of battery connections: +ve use red lead, -ve use black lead. PAK200467-HW_01A March 2020 2020 Honeywell Security...
  • Page 6: Preventative Maintenance

    CAUTION Dispose of used batteries according to the battery manufacturer’s instructions and all local and national regulations. PAK200467-HW_01A March 2020 2020 Honeywell Security...
  • Page 7 This page has been intentionally left blank. PAK200467-HW_01A March 2020 2020 Honeywell Security...
  • Page 8 PAK200467-HW_01A March 2020 2020 Honeywell Security...

This manual is also suitable for:

Ps-hl-13805bm-4opPs-hl-13810bm-8op