Daikin Rotex RHOB12AAV1 Installation Instructions Manual page 39

Table of Contents

Advertisement

E
Min. flow temperature at OT
(OpenTherm) or RF thermostat
E.
Reaction OT and RF room thermostat
F
Start rpm CH
F.
Start rpm hot water
h
Max. rpm fan (* 100 rpm)
n
Regulated flow temperature during boiler
operation (Ta)
n.
Keep hot water temperature at
Comfort/Eco
O.
Delay time CH request response
o
Delay time CH operation after hot water
operation
o.
Number of eco days
P
Anti-recycling time during CH operation
P.
Reference value hot water
ROTEX Heating Systems GmbH
40
40
40
Settings reach 10 – 60°C
1
1
1
0= do not respond to CH request if requested temperature is
lower than the set value par. E
1= respond to CH request with minimum flow water temperature
limited to set value par. E
2= respond to CH request with maximum flow temperature as
set in the display (on/off function)
70
70
50
Settings reach 50 - 99% of the set maximum rpm
70
70
50
Settings reach 50 - 99% of the set maximum rpm
45
46
65
Setting reach 40 – 50 (RHOB12AAV1 and RHOB18AAV1) or
60 – 70 (RHOB42AAV1)
This parameter can be used to set the maximum rpm
85
85
85
Setting reach 60°C - 90°C
0
0
0
Setting reach: 0 or 40°C – 60°C
0= reheating temperature is equal to hot water temperature
0
0
0
Settings reach 0 – 15 minutes
0
0
0
Settings reach 0 – 15 minutes
3
3
3
Settings reach 1 - 10
5
5
5
Minimum switch off time on CH operation
Can be set to 0 - 15 minutes
36
36
36
Not applicable for heating only boilers.