Parameter Settings

After the installation and wiring is done, connect the charger using the app or a
computer and configure parameters. The charger is then ready for use.
Computer parameter Settings
(Installation Engineers Only)
Connect the charger to a computer via a network cable. Open the web browser and type
in 192.168.1.5:8080 in the address field and click enter, then the parameter setting page
of the charger will open up.
Parameter setting can only be done via web browser on a computer. It is suggested to
use microsoft edge or chrome (other browser might have compatibility problems).
1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
20
2
22
2
24
2
2
2
28
29
Computer parameter Settings Explained
1. Firmware version of the Charger. This item cannot be modified here on the setting
page.
2. Charger ID: this is the unique identification of the Charger. If the charger is to be
connected to Project EV back-office server, this ID must be set as the serial number on
the nameplate of the Charger. Otherwise the Charger cannot be registered on the server.
3. Charger IP: The default IP is 192.168.1.5. It is not suggested to change the default IP. If
you have changed the default IP and forgot the new IP, you can reset the charger to
factory setting by long press the reset button(the reset button on control board, not the
emergency stop button) until the charger reboot. Then you can use the default
192.168.1.5 for access.
Please note: ID(same as serial number, can be found on the nameplate sticker) and server
url, otherwise the charger won't be connected to the back-office server. After restoring
the charger to factory setting, you'll need to reset the charger
4. Charger Subnet mask: The default value is 255.255.255.0. It is not suggested to change.
If the subnet mask has been reset to other value and you have forgotten the new value,
you can restore the charger to factory setting by long press the reset button.