Thank you for choosing Project EV Charging Equipment ATESS EVD series intelligent DC charging equipment is a device that provides high-efficiency, safe and stable DC power supply for electric vehicles, which has a friendly man-machine interface and integrates corresponding functions of control, billing, communication and security protection.
Page 4
LED Sequence Blue - Standby (The charging equipment can only be used when the blue light is lit) Red - Steady on/flashing (Fault) Green - Steady on (Charging in process) Green Flashing - Establishing Communication Yellow Flashing - System Initialising Internal view and terminal definition AC input RCBO AC input terminal block.
Packaging List Packaging List Item Quantity Remark Mode Charging Equipment User Manual Certificate of Quality Mounting Bracket Already installed on the rear side of the charging equipment Cable Hooker Hex Head expansion bolt, M8*80/304 stainless steel Installation and Wiring 1. Firstly, according to regulation BS7671 18th Edition, the screen should be 1.2m-1.4m from the ground.
Page 6
2. Loosen the 2 screws at the bottom of the charging equipment that fixes the mounting bracket. Keep them safe for later use. Place the mounting bracket onto the bolts and screw the nuts and washers on. Take out the cable hook and fix it using the same procedure.
Page 7
4. Using a suitable cable, we suggest you use a 5-core cable(with CPC included). For your convenience, a cable gland is provided. Unlock the unit, and open the door. Connect the cables into the terminal block, through the cable gland on the bottom right-hand side and secure them.
Page 8
Parameter Configuration After the charger is installed and connected, the charging equipment must be configured according to the actual needs of the user. Home page configured through the LCD touch screen. Save the changes, exit the menu before using the charging equipment as normal.
System Parameters Parameters Function Description RFID Card PIN code setting of RFID reader, a 6-digit code, PIN Code the default setting is 242007. It must be the same with the PIN code of user card. Users can also use other PIN code if they have card writer to change PIN code of user card.
Network Parameters Network parameters need to be configured when the charging station needs to be connected to back office server, for operation and management. Network parameters include server parameters, and change parameters. The charging equipment can support LAN connection, WIFI and 4G. Parameters Function Description Server URL 1...
Protection Parameters The protection-related parameters - Including voltage, current and temperature. Parameters Function Description DC Output Over voltage limit setting of DC output overvoltage value DC output Over current limit setting of DC output overcurrent value AC input Over voltage limit setting of AC input overvoltage value AC input Under voltage limit setting of AC input...
Operation Instruction and LCD Introduction Charging mode and operation APP/RFID Mode: Initiate or cease charging by scanning QR code using APP or by swiping RFID card. You can also use APP for reservation and payment provided that the back-office server supports such function. QR Code APP/RFID Mode operation process flow...
Plug and Charge Mode: Charging will start automatically after EV vehicle plugged into charger. If you want to stop the charging, just press the stop icon on the screen. Plug & Charge mode operation process flow LCD Interface Introduction The charging equipment is equipped with a 4.3 inch screen. The content is displayed as below: When powered up, the charging equipment will...
Page 14
Management page, user can set different kinds of parameters here. Password authentication is required when entering each parameter setting page. Password window. Before entering numerics, please first press the blank bar above the keypad, before following the instruction below. Using the keyboard that appears, you can type in the 4- digit password.
Page 15
Network parameters page, used to set network related parameters of back-office server and the charging equipment. Protection parameters page of DC output, used to set limit value of voltage, current, power and temperature. Fault record page - User can check history of faults here. Charging record page...
Fault Codes The table below outlines the type of faults which may appear on your EV charger. Fault Description Emergency stop is activated RFID Communication fault Over temperature fault Surge protection fault Power module communication fault Meter communication fault DC output overvoltage fault DC output overcurrent fault BMS communication timeout Insulation detection timeout...
Page 17
Charger Specification Model EVD-40D-P Dimension (mm) 775*556*270 (WD*H) Weight (KG) 80KG Display Casing Material Stainless steel & acrylic sheet AC Input Grid Connection 400V, 3 phase 5 wires Voltage AC 320~475V Current Frequency 45~65Hz DC Output Plug Type Voltage DC150~750V...
Protection Features Low and high trip limit of AC input voltage Adjustable within 260~457V AC Over voltage trip limit of DC output Adjustable within 260V~778V DC Over temperature protection Derate since 50˚c; Stop at 75˚c Short circuit protection Emergency stop protection Leakage Protection Type A Lightning Protection...
(These warranty terms are only applicable to UK consumers only for the ATESS EV chargers, bought through the authorized repair and installation partner) Welcome to Project EV and ATESS, and thanks for choosing our Electric Vehicle charge point. All our products are backed by a 5-year warranty (3-years parts and labour plus 2 years parts) giving you years of trouble-free charging.
Page 20
1. Warranted Products This 5 Year limited warranty shall only apply to EV Chargers AC/DC only installation up to 300kW installed and provided by an Authorized 5 Year Warranty Installer. 2. 5 Year Limited Warranty A. 5 years Limited Product Warranty ATESS warrants its EV chargers, known as ‘ATESS Products’...
Page 21
3. Exclusions and Limitations The aforementioned “Limited Warranty” does not apply to any ATESS Products which have been subjected to: A. If the direct customers who has obtained the ATESS Products from ATESS or its distributor failed to pay the ATESS Products according to the purchase price, ATESS is entitled to reject the claim under this warranty based on this provision.
Page 22
B. The direct customer shall notify the warranty claims to Authorized 5 Year Warranty Installer or its Distributor within 1 week via email only after becoming aware of the circumstances which constitute a warranty case. The report shall include the following information: 1.
Page 23
EV charger spare parts and service costs are assessed each year, subject to the latest prices. ATESS reserves the right to interpret other unmentioned matters. 4|Page 9. Contact In the first instance please contact your installer or failing this please contact Project EV https://www.projectev.co.uk/...
Page 24
Company Address: Unit 1 Lakes Court, Lancaster Business Park, Newborough Road, Needwood, Burton Upon Trent, Staffordshire, DE13 9PD Website: www.projectev.co.uk Contact Number: 0800 599 9582 General Enquiries Email: enquiries@projectev.co.uk Pro App Email: proapp@projectev.co.uk This user manual is correct as of 02/2023...
Need help?
Do you have a question about the EVD-40D and is the answer not in the manual?
Questions and answers