External Interface Manual
Requirements
At least one voting application is running and the Hall Display setting in the voting application is set to "On".
2.2.2.17.

Topic = VOTING, data-item = RESQUO#

Purpose
Returns the quorum contents of Results window 1 (# = 1) or 2 (# = 2) on the PC screen. Will only return data
if quorum enabled and not equal 'none'.
Layout
"required quorum, authorised present"
where:
required quorum
authorised present
Requirements
At least one voting application is running and the Hall Display setting in the voting application is set to "On".
Only for Parliamentary and For/Against kind of voting and if quorum is enabled.
2.2.2.18.

Topic = VOTING, data-item = RESMAJ#

Purpose
Returns the majority contents of Results window 1 (# = 1) or 2 (# = 2) on the PC screen. Will only return data
if majority enabled and not equal 'none'.
Layout
"required majority, majority"
where:
required majority
majority
Requirements
At least one voting application is running and the Hall Display setting in the voting application is set to "On".
Only for Parliamentary and For/Against kind of voting and if majority is enabled.
2.2.2.19.

Topic = VOTING, data-item = RESAPPR

Purpose
Returns whether or not the current (active in control window) voting is approved.
Layout
"voting result"
where:
voting result
Requirements
At least one voting application is running and the Hall Display setting in the voting application is set to "On".
Only for Parliamentary and For/Against kind of voting, motion approved text enabled, majority is enabled and
the majority name not equal 'none'.
2.2.2.20.

Topic = VOTING, data-item = ACTQUO

Purpose
Returns the actual data regarding the quorum settings. Will only return data if majority enabled and not equal
'none'.
Layout
"quorum name, required quorum, authorised delegates"
where:
quorum name
required quorum
authorised delegates
Requirements
At least one voting application is running and the Hall Display setting in the voting application is set to "On".
Only for Parliamentary and For/Against kind of voting and if quorum is enabled.
Bosch Security Systems B.V. | 2004 April | External Interface Manual
the number of delegates which must be present.
the number of delegates present with voting authorization.
the number of delegates which must approve the voting before
the voting can be accepted.
the number of delegates which approve the voting.
this will be empty if the vote is running.
When the vote is stopped it will contain the result of the voting.
I.e. "YES" if the quorum is reached (if quorum is used) and
majority is reached. Otherwise "NO" will be returned.
the name of the quorum calculation algorithm currently used. A
string of at most 10 characters.
the number of delegates which must be present.
the number of delegates present with voting authorisation.