Male
Union
2.1.2 2" Plumbing
Take a hacksaw and cut 8 ¾ inches out of the pipe after the filter. The electrode can be
installed horizontally or vertically.
them on the remaining pipe ends. Slide in the electrode and hand tighten the female union to
the male union.
2.2
Connecting the Electronics Unit to the Electrode
Locate the male spades found at each side of the electrode (Page 8; Figure 3). Connect
the female plug located at the end of the wire from the electronics unit and it to the male spade
located on the electrode (Figure 4). Attach the unconnected wire for the electronics unit to the
other side of the electrode (Figure 5). It does not matter which wire plugs into which side of
the electrode. The polarity will alternate the current between the two copper bars on the
electrode. Figure 6 illustrates the proper connection for the electronics unit to the electrode.
Bushing
Reducer
Figure 3
Take the male half of each union and clean and cement