Drive Mounting - Seagate Surveillance HDD Product Manual

Table of Contents

Advertisement

3.4

Drive mounting

Users can mount the drive in any orientation using four screws in the side-mounting holes or four screws in the bottom-mounting holes.
Figure 3
Refer to
for drive mounting dimensions. Follow these important mounting precautions when mounting the drive:
• Allow a minimum clearance of 0.030 inches (0.76mm) around the entire perimeter of the drive for cooling.
• Use only 6-32 UNC mounting screws.
• The screws should be inserted no more than 0.120 inch (3.05mm) into the bottom or side mounting holes.
• Do not overtighten the mounting screws (maximum torque: 6 inch-lb).
Figure 3
Mounting dimensions
4X 6-32 UNC 2B
3 MIN THREAD DEPTH
.1 MAX FASTENER PENETRATION
MOUNTING HOLES BOTH SIDES.
MAX TORQUE 6 IN/LBS
2X 1.750±.010
2X 1.625±.010
1.432±.019 2
.128±.010
TEMPERATURE
CHECKPOINT 60°C MAX
Seagate Surveillance HDD Product Manual, Rev. B (Draft 2)
C L OF CONN
.814±.020 2
C L OF DRIVE
3.750±.010
4.000±.010
C L OF DRIVE
2.000
2X 4.000±.010
2X 1.638±.010
2X 1.122±.010
Y
.250±.010
Z
.138±.015 2
Z
1.028 MAX
26.11 MM
5.787 MAX
146.99 MM
Y
6X 6-32 UNC 2B
3 MIN THREAD DEPTH
.1 MAX FASTENER PENETRATION
MOUNTING HOLES BOTH SIDES.
MAX TORQUE 6 IN/LBS
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

St6000vx0003

Table of Contents