59SC6A: Installation, Start-up, Operating and Service and Maintenance Instructions
device. See Thermidistat, Zone Controller, thermostat, or controller
manufacturer's instructions for proper connection.
NOTE: For 24-V & 115-V EAC or Humidifier Accessory details, see
Accessory instructions.
Alternate Power Supplies
This furnace is designed to operate on utility generated power which has
a smooth sinusoidal waveform. If the furnace is to be operated on a
generator or other alternate power supply, the alternate power supply
must produce a smooth sinusoidal waveform for compatibility with the
furnace electronics. The alternate power supply must generate the same
voltage, phase, and frequency (Hz) as shown in
rating plate.
Power from an alternate power supply that is non-sinusoidal may
damage the furnace electronics or cause erratic operation.
Contact the alternate power supply manufacturer for specifications and
details.
Fig. 37 – Field-Supplied Isolation Relay for Humidifiers with
Internal Power Supply
Fig. 38 – Example of Single Stage Furnace Control
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 11
or the furnace
A11157
A210192
Fig. 39 – Thermostat Wiring Diagrams for Single Stage Furnace
Notes for thermostat wiring diagrams:
1. Thermostat output signals may vary. Consult thermostat installation
2. Refer to outdoor equipment Installation Instructions for additional
3. Configure the thermostat for air conditioner installations. Refer to
4. Configure thermostat for HYBRID HEAT®
5. Heat pump MUST have a high-pressure switch for HYBRID
6. For Single-stage AC or HP, configure thermostat for single-stage
7. NO connection should be made to the furnace HUM terminal when
28
THERMOSTAT
NOTE 7
See notes 1, 2, 3, 6, 7 and 8
Single-Stage Furnace with Single-Speed Air Conditioner
THERMOSTAT
NOTE 7
See notes 1, 2, 3, 4, 5, 6, 7 and 8
Single-Stage Furnace with Single-Speed Heat Pump
with Single-Speed A/C & Heat Pump
instructions for more information.
information and setup procedure.
thermostat instructions.
Refer to thermostat instructions.
HEAT® dual fuel applications.
compressor operation. Refer to thermostat instructions.
utilizing the thermostat's 24-volt humidifier output.
A230219
A230220
dual fuel operation.