a 0, the built-in communicator is disabled and the NX-6V2
functions as a local-only control.
Table 4 communicator formats
Data
Format
0
Local
1
Universal 4+2
2
3+1 fast (or 4+1)
3
Reserved
4
Pager
5
3/1 or 4/1 slow
6
3/1 or 4/1 slow
7
3/1 or 4/1 fast
8
3/1 or 4/1 fast
9
3/1 or 4/1 fast with
parity
10
3/1 or 4/1 fast with
parity
11
4+2 express
12
4+2 fast
13
Ademco contact ID
14
SIA
15
Custom format
16
3/1 or 4/1 slow
17
3/1 or 4/1 slow
18
3/1 or 4/1 fast
19
3/1 or 4/1 fast
20
3/1 or 4/1 fast with
parity
21
3/1 or 4/1 fast with
parity
22
SIA
[1] pulses per second
4
Description
Communicator is disabled
Two-digit event code 1800 Hz transmit
2300 Hz handshake double round parity
40 pps [1]
One-digit event code 1900 Hz transmit
1400 Hz handshake double round parity
20 pps
Reserved
Two-digit event code DTMF
transmission
1800 Hz transmit 2300 Hz handshake
double round parity 20 pps hex
capability
1800 Hz transmit 1400 Hz handshake
double round parity 20 pps hex
capability
1800 Hz transmit 2300 Hz handshake
double round parity 40 pps hex
capability
1800 Hz transmit 1400 Hz handshake
double round parity 40 pps hex
capability
1800 Hz transmit 2300 Hz handshake
single round parity 40 pps hex capability
1800 Hz transmit 1400 Hz handshake
single round parity 40 pps hex capability
Two-digit event code DTMF
transmission
Two-digit event code 1900 Hz transmit
1400 Hz handshake double round parity
20 pps
DTMF
Frequency shift keys
See Loc
Same as 5, but sends the alarm event
code rather than the zone number
Same as 6, but sends the alarm event
code rather than the zone number
Same as 7, but sends the alarm event
code rather than the zone number
Same as 8, but sends the alarm event
code rather than the zone number
Same as 9, but sends the alarm event
code rather than the zone number
Same as 10, but sends the alarm event
code rather than the zone number
SIA with area modifiers
Location 3 - Phone 1 dial attempts/backup control
Location 3 has two segments of numerical data.
Segment 1 - Phone 1 dial attempts
Program the number of dial attempts (1 to 15) the
communicator makes to phone 1 before ending the notification
process. The default is 8, which means that the communicator
makes eight attempts to the first number.
Segment 2 - Phone 1 backup control
Program the backup control for phone 1. The default is 0.
•
Program a 0 in segment 2 to cause the NX-6V2 to make
the designated number of attempts to phone 2 before
setting the fail to communicate condition to stop reporting.
•
Program a 1 in segment 2 to cause the NX-6V2 to stop
trying to communicate after the designated number of
attempts have been made to phone 1.
•
Program a 2 in segment 2 to cause the NX-6V2 to make
the dial attempts in increments of two. The first two
attempts are made to phone 1, the next two attempts to
phone 2. This repeats until the total number of attempts
designated in segment 1 is completed.
Location 4 - Phone 1 events reported
Location 4 has two segments of feature selection data. Use
this location to select those events reported to phone 1.
•
If you do not want dual or split reporting, use Location 4 to
select all events to phone 1.
•
If you want dual or split reporting and the split is based on
the event type (alarm, open/close, etc.), use Location 4 to
select only those events that are reported to phone 1.
•
If you don't want events reported to phone 1, program 0 in
Location 4 (disabling all options).
Segment 1
1. Alarms and alarm restores.
2. Opening and closings.
3. Zone bypass and bypass restores.
4. Zone trouble and trouble restores.
5. Power fail, low battery, power restore, and low battery
restore.
6. Bell cut, telephone line cut, bell cut restore, telephone line
restore.
7. Test reports.
8. Start and end programming, download complete.