Site Preparation - Kohler PILLOW TALK POWER LITE K-3379 Installation Instructions Manual

Vitreous china toilet
Hide thumbs Also See for PILLOW TALK POWER LITE K-3379:
Table of Contents

Advertisement

Available languages

Available languages

2. SITE PREPARATION

A. INSTALL ELECTRICAL SERVICE
Have a licensed electrician install a properly grounded,
grounding-type receptacle, protected by a Class A Ground-Fault
Circuit-Interrupter (GFCI).
The electrician should locate the receptacle 6" (15.2cm) above the
floor line and 2-3/4" (7cm) to the right of the centerline of the closet
flange. The electrical cord length of the toilet is 3' (91.4cm).
NOTICE:
Follow all local electrical codes.
B. REMOVE EXISTING TOILET
NOTICE:
Carefully inspect new fixture for any sign of
damage before removing existing toilet.
Turn off water supply.
Flush the toilet and sponge out remaining water from tank and bowl.
Disconnect supply valve and remove old tank and bowl.
See Fig. #2 . Remove old gasket from the floor and closet flange
with a putty knife.
Remove old T-bolts (the T-shaped bolts in the closet flange) and
discard.
DANGER: Risk of hazardous gases. If new toilet is not
installed immediately, temporarily stuff a rag in the closet
flange.
C. ROUGH-IN PLUMBING
Turn off water supply.
Install or relocate supplies and outlets as necessary to conform to
roughing-in dimensions. See Fig. #3 . For shut-off valve location,
see Fig. #4 .
A
1007265-2-
2
GFCI-Protected
Receptacle
6" (15.2cm)
2-3/4"
(7cm)
Fig. #1
Closet Flange
Fig. #2
Kohler Co., Kohler, WI U.S.A.