CONSIDERATIONS WHEN USING THE TORC SYSTEM Only Stonehealth inducted and authorised operators may use the TORC System. A nominated person adjacent, other than the Operator, should be aware of how to safely shut down the system in unforeseen circumstances. Whilst personnel working in the vicinity need not be inducted into the working of the system, they should be made fully aware of the potential hazards.
Ensure the correct PPE is used at all times. Max inlet water pressure is 2BAR. If higher use pressure reducer provided. WHILST STONEHEALTH HAVE MADE EVERY EFFORT TO GIVE APPROPRIATE GENERAL GUIDANCE, THE EQUIPMENT MUST COMPLY WITH AND BE USED IN ACCORDANCE WITH ANY REGULATION...
ORIGINAL INSTRUCTIONS Specification AIR CONSUMPTION PRESSURE 6 - 8 BAR Max VOLUME 125 CFM Min MASS PRESSURE POT 65Kg PUMP/AIR COOLER 25Kg RATED TEMP +5 - 35 Degrees C FLOW RATE 0.5 to 1.5 L/min AUXILIARY PUMP SPEC POWER 110 | 115 | 230 Volts FREQUENCY 50 | 60 H2 Noise level at operator position is 99.1dB (Max at nozzle.) Ambient temperature range for...
ORIGINAL INSTRUCTIONS Checklist of Parts Required Pressure Pot. Air Cooler / Pump Unit. Short Yellow Hose. Hose Set inc Nozzle. Site Requirements 125 CFM Air Compressor. Clean cold water supply with a positive pressure. Max 2BAR. Suitable PPE for the task being performed. Hose Set inc Nozzle.
1) Connect the Air Compressor to Inlet of the Air Cooler. Connect the Air Cooler to the Pressure Pot. Connect Inlet Water to Air Cooler. The TORC requires a positive Connect the Blast Hose to the Pressure Pot. pressure supply with no more than a 2BAR pressure.
Page 8
ORIGINAL INSTRUCTIONS Quick Setup Guide 5) Connect the Dead Man Hose to the Pressure Pot. Connect the Water Outlet Hose to the Air Cooler. 7) Now turn on the water supply. 8) Check the Water Separator Bleed Valve. This water separator is a secondary manual unit.
Page 9
9) Adjust pressure using the Pressure Regulator. Push down to lock. Adjust the Vibro Pressure using the Ball Valve. Control and adjust TORC Head using the Dead-man Leaver and Water Add appropriate granulate to the TORC Pressure Pot Hopper. Always Valves.
Visually inspect hose couplings daily and replace rubber seals if damaged. Stonehealth stock a full range of spare parts. Due to the nature of the system, we recommend only using parts supplied by Stonehealth and will need to be fitted by a competent person.
National Trust, English Heritage, Historic Scotland, CADW and other worldwide conservation bodies. Stonehealth is proud of its reputation in providing solutions with integrity and setting new standards of restoration and technology excellence in the stone industry.
Page 14
The Stonehealth TORC User Guide STONEHEALTH.COM...