Galvin Specialised Safe-Cell 50110C Installation Manuallines

Ezy-grip basin tapware

Advertisement

Quick Links

Safe-Cell
®
Ezy-Grip Basin Tapware
PRODUCT CODE:
- 50110C
SPECIFICATIONS
Designed for maximum protection against vandalism, Safe-Cell
duty components and can be installed from the rear.
Ideal for high risk facilities such as prisons, detention centres, mental health and behaviour centres.
The basin assembly is finished in bright chrome plate for easy cleaning and durability.
Quarter turn ceramic disc.
Anti-ligature and tamper resistant design.
IMPORTANT: All Safe-Cell
our premises in good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without
notice.
PRE-INSTALLATION - MOUNTING DETAILS
If the mounting holes do not already exist, mark out and drill the holes in the bench/trough, as shown in
rough-in dimensions.
Note: Distance between outlet and basin bodies is 218mm maximum.
33
218mm MAX
ROUGH-IN DIMENSIONS
Ezy-Grip basin sets are tested in accordance with AS/NZS 3718 and leave
®
59
22
1/2" BSP/CU
basin assemblies are made from heavy
®
Min
Max
Min
Max
1/2" BSP
218
MAX
Version 2, 6 September 2017, 1 of 4
½" CU / BSP
Aerator
Ceramic
50
500
5
75
7
Chrome
67
NOM
25
22
MAX
V/R AERATOR
6LPM
100

Advertisement

loading

Summary of Contents for Galvin Specialised Safe-Cell 50110C

  • Page 1 Nominal Flow Rate (LPM) Finish Chrome NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice. PRE-INSTALLATION - MOUNTING DETAILS If the mounting holes do not already exist, mark out and drill the holes in the bench/trough, as shown in ...
  • Page 2 Thread tape/sealant INSTALLATION IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or tate standards. Failing to comply with these provisions shall void the product warranty and may affect the performance of the product.
  • Page 3 Version 2, 6 September 2017, 3 of 4 5. Secure basin body assembly 6. Fit dress flanges Secure in place with supplied washer and locking   Fit washer onto dress flange and tighten. nut. Ensure that the set is installed with hot and cold ...
  • Page 4 Version 2, 6 September 2017, 4 of 4 TROUBLESHOOTING PROBLEM CAUSE RECTIFICATION Water is not flowing from Water supply not on Turn water on Remove aerator or flow regulator from Aerator or flow regulator is blocked by tap and remove debris. Install an inline debris strainer to stop further blockages.