5. Disconnect the hose that connects to the
glass clean nozzle.
6. Pull the nozzle out from the inside of the
gasket. There is a notch for positioning when
reinstalling.
7. Disconnect the fill hose from the gasket. It
is a resistance fit to the gasket. Pull it out of
the opening. No need to disconnect the hose
clamp.
8. Remove the LED tub light by pushing it
through to the outside of the gasket.
9. To remove the damper from the gasket,
remove one Phillips-head screw from the
clamp securing the damper to the gasket.
10. Remove the inner clamp using a 9/32 socket,
turning counter-clockwise (CCW).
11. Pull the clamp and gasket away from the tub.
– 46 –
(Continued next page)