Samsung UE40C69 VS Series Service Manual page 57

Table of Contents

Advertisement

4-1-1. No Power
The LEDs on the front panel do not work when connecting the power cord.
-
Symptom
The SMPS relay does not work when connecting the power cord.
-
The units appears to be dead.
-
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
-
Major
checkpoints
Check the fuses of each part.
-
Check the output voltage of SMPS.
-
Replace the Main Board.
-
Diagnostics
Make sure to disconnect the power before working on the IP board.
Caution
Power indicator LED is on?
Yes
Check the backlight on,
when 18p cable unconnected ?
Yes
Check 'Stand-By 5V' ?
- BD1024 : A5V
Yes
Check 'Main power input' ?
- BD1026 : B12VS
- BD1019: B13V
- BD1023 : B5V
Yes
Check Output of 'Stand-By Power IC' ?
- Pin#3 of IC402 : A3.3V
Yes
Check Output of 'Power IC' ?
L1002 : B3.3V
L1003 : B1.2V
L1004 : VAL_1.1V
L1001 : DDR_1.8V
Yes
Check Input power of 'T-con b'd'
- F1(T-CON) : B13V
Yes
Check Power of 'T-con b'd'.
- L9(T-CON) : VCC12
- TP_VCC33 : VCC33
Yes
Please, Contact tech support.
No
Check a connetion power code.
No
No
Change 18p cable.
Change Main Power Assy.
No
No
Change the Main Assy.
No
Reconnect or Change the LVDS
No
cable.
No
Change the T-con B'd.
4. Troubleshooting
4-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ue46c69 vs seriesUe55c69 vs seriesUe40c69 vk seriesUe46c69 vk seriesUe55c69 vk seriesUe40c6990vs

Table of Contents