Attach the insulating tape to the FPCs that are not connected so that
CAUTION
those FPCs will not short-circuit.
(3)Connect the FPCs to the Back Cover Ass'y (2 places).
(4)Attach the DC coupler, turn on the power, and set the camera to manual cleaning mode.
(5)Set the camera on the Flange Back Tester and measure the flange back.
(6)If the flange back is outside the standard, make flange back adjustment once again.