2.2 Flange Back Measurement (with the Flange Back Tester)
When  using  the  Flange  Back  Tester,  follow  the  instruction  manual 
CAUTION
supplied with the product and the explanation on preparation below.
<Preparation>
1) Checking of the power cable
      Make sure to check for any damage or brakeage of the power cable before connecting 
it to the tester. The power cable is not provided with this tool, so one that meets local 
standards should be purchased.
                          Voltage: Depends on the country
                          Electric power: 60VA
2)   A ging and Calibration of the Reference Surface
  (1)  C heck for dust and dirt on the mount reference surface (including jigs) and the sensor 
part of the flange back tools.
  (2)    I ncreases in internal temperature will affect the measurement results, so perform aging 
for 1 hour or more before measuring the flange back and perform reference surface 
calibration with the special calibration tool.
  (3)    W hen flange back is measured more than 1 hour after the previous reference surface 
calibration, perform the reference surface calibration with the special calibration tool 
before measuring.