Download Print this page

LEGRAND DA2400 Owner's Manual page 6

Poe injector

Advertisement

1.2 Installation
The DA2400 4 Port PoE Injector is best installed during new construction in two steps; at "rough-in"
after the Electricians are done, but prior to drywall being installed, and at "trim-out" after the drywall is
installed and painted. These steps are detailed below:
A. "Rough-in" steps:
1. A single dedicated Cat 5 should be run in the walls from the structured wiring enclosure
location in the home where the 4 Port PoE Injector will be installed to each location in the
home where an IEEE 802.3af device will be installed (leave extra cable at both ends).
NOTE: Run Cat 5 cable at least 12" from electrical cabling (preferably in a separate stud
cavity) and cross electrical cables at a 90° angle. Use loose Velcro-style cable ties for
bundling. If stapling is required, use specialty staples to avoid compressing the cable.
2. At the selected locations, refer to the installation instructions provided with the IEEE 802.3af
device for recommended use of electrical gang boxes or low voltage brackets, with the extra
Cat 5 cable in the box, or attached in such a way that it may be fished out after the drywall is
installed.
B. "Trim-out" steps:
1. The Cat 5 cable that was secured at each of the locations should be pulled out and
terminated with an RJ45 plug following standard TIA 568A recommendations and attached to
the IEEE 802.3af device which is then installed.
2. In the structured wiring enclosure the Cat 5 cables from the remote locations are terminated
with RJ45 plugs for direct connection to the DA2400 "Data and Power" output jacks once the
DA2400 is installed.
3. Each 4 Port PoE Injector is first attached to the separately available AC1025 bracket using
two of the eight screws provided with the bracket (see Figure 2) and then the bracket is
installed in the structured wiring enclosure by slipping the tabs into the square holes, and
using the push pins in round holes to secure the DA2400.
NOTE: Two of the air holes in each side of DA2400 are threaded to facilitate installation on
the AC1025 bracket.
4. Cat 5 patch cables (available separately) are then connected from an installed switch or
router to the "Data" ports on the 4-Port PoE Injector.
5. The 4 Port PoE Injector is powered with an AC to DC adapter which also needs to be
plugged in to an AC source.
NOTE: If the DA2400 is going to be wall mounted, use the keyhole slots on the rear of the
unit by hanging it on the screws that are first installed in the wall or on a piece of plywood.
301 Fulling Mill Road, Suite G