● SAFETY WARNING(AS4777.2:2020 CL7.3.1, CL 7.3.3, CL7.3.5)
Any installation and operation on BESS must be performed by qualified electricians,
in compliance with standards, wiring rules or requirements of local grid authorities
or companies (like AS 4777 and AS/ NZS 3000 in Australia).
Before any wiring connection or electrical operation on BESS, all battery and AC
power must be disconnected from BESS for at least 5 minutes to make sure BESS is
totally isolated to avoid electric shock.
The temperature of BESS surface might exceed 60℃ during working, so please make sure
it is cooled down before touching it, and make sure the BESS is untouchable for children.
Usage and operation of the BESS must follow instructions in this user manual,
otherwise the protection design might be useless and warranty for the BESS will be
invalid.
Do not open BESS cover or change any component without WIFO PRO ' s
authorization, otherwise the warranty commitment for the BESS will be invalid.
Appropriate methods must be adopted to protect BESS from static damage. Any
damage caused by static is not warranted by WIFO PRO.
The neutral continuity is maintained already internally when changing from on-grid to
standalone mode, no need external wiring.
This BESS includes an integrated residual current device (RCD).
If an external residual current device (RCD) is used, a device of type A should be used, with
a tripping current of 30 mA or higher.
This BESS uses active anti-islanding protection, the method is shifting the frequency of the
inverter away from nominal conditions in the absence of a reference frequency (frequency
shift).
This BESS is a multiple mode inverter, it is used for outdoor unconditioned without solar
effects. The maximum operating ambient temperature is 55 ℃.