Keysight Technologies Y1245A Installation Manual
Keysight Technologies Y1245A Installation Manual

Keysight Technologies Y1245A Installation Manual

Single site signal cable

Advertisement

Quick Links

Keysight Y1245A, Y1246A and Y1247A
Single Site Signal Cable
Keysight's Y1245A, Y1246A and Y1247A are the same
cable but different lengths; the Y1245A cable is 0.5
meters long, the Y1246A cable is 1 meter long and the
Y1247A cable is 2 meters long. These cables contain 60
micro coax lines for 16 channels, 16 PPMU sense, 4 high
voltage, and 4 Open Drain lines. 60-Pin Male Edge Rate
to Male Edge Rate connectors with squeeze latches are
used on the cable. The cables also include an alternate
thumb screw hood. One end of this cable plugs onto the
M9195A/B front panel connector. The other end is
available to connect to your Device Under Test (DUT) or
the Keysight Y1253A Evaluation and Prototyping Kit.
Refer to the M9195A Startup Guide and User Guide for detailed information on using the various signal lines.
General Use Recommendations
Keysight recommends that you use one of the following three Samtec
your Device Under Test (DUT) end connector on the cable:
ERF8-030-01-L-D-RA-L-TR (right angle)
ERF8-030-01-L-D-EM2-TR (edge mount, for use on 0.062"thick PC boards)
ERF8-030-05.0-L-DV-L-TR (vertical mount)
Installation and Removal of the Y1246A/Y1247A Cable
The end of the cable that connects to the M9195A has a single thumb screw on the hood. Connect the cable to
the M9195A/B and then hand-tighten the thumb screw to the attached hex standoff on the module. See the
following photographs.
1
Samtec,
http://www.samtec.com
Optional
thumbscrew hood
60-pin mating connectors to mate with
1
Hand tighten thumbscrew

Advertisement

loading
Need help?

Need help?

Do you have a question about the Y1245A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Keysight Technologies Y1245A

  • Page 1 Keysight Y1245A, Y1246A and Y1247A Single Site Signal Cable Keysight’s Y1245A, Y1246A and Y1247A are the same cable but different lengths; the Y1245A cable is 0.5 meters long, the Y1246A cable is 1 meter long and the Optional Y1247A cable is 2 meters long. These cables contain 60...
  • Page 2 Pinout of the DUT cable connector This pinout is the same as the pinout on the M9195A/B DSR module. Latch/GND Pin # Pin # Latch/GND Channel 03 Channel 00 Channel 01 Channel 02 Channel 07 Channel 06 Channel 05 Channel 04 HV22 HV23 HV21...
  • Page 3 Installation and Removal of the Alternate Thumbscrew Hood The alternate hood uses thumb screws to retain the cable to the DUT rather than the squeeze latches of the original hood. To use the alternate hood on the DUT end of the cable, the old hood must first be removed (requires Torx T-5 screwdriver).
  • Page 4 CONTAINED HEREIN, INCLUDING BUT NOT LIMITED or contract clause. Use, duplication or disclosure of TO THE IMPLIED WARRANTIES OF Software is subject to Keysight Technologies’ standard MERCHANTABILITY AND FITNESS FOR A commercial license terms, and non-DOD Departments and PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE Agencies of the U.S.

This manual is also suitable for:

Y1246aY1247a