Advertisement

Quick Links

Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 1
Malvern II Classic
Thank you for purchasing an ACR Heat Products stove
MULTI
FUEL
SMOKE
EXEMPT
AIRWASH
SYSTEM
10
10
YEAR
YEAR
WARRANTY
Serial Number:
Multifuel Stove Model • MAL2CL
To be retained by the user for future reference
MAL2CL 0101 • Version 1 Date 18/07/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Malvern II Classic and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ACR STOVES Malvern II Classic

  • Page 1 Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 1 Malvern II Classic Multifuel Stove Model • MAL2CL To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove MULTI FUEL SMOKE EXEMPT AIRWASH SYSTEM...
  • Page 2 Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 2 IMPORTANT INFORMATION To ensure that you gain the most from your purchase, please take a few minutes to read through this manual before lighting the appliance for the first time. Since April 2002 only registered competent installers can install solid fuel appliances. Installations carried out by non-registered installers must be inspected by local authority building control.
  • Page 3 Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 3 Malvern II Classic Specifications Nominal heat output 5 kW - Wood 5 kW - Maxibrite Chimney draft required 12Pa Height 551 mm Width 491 mm Depth 331 mm Weight 82 kg Air Requirement...
  • Page 4 • Malvern II Classic area. It is also an offence to acquire an (MAL2CL) has been "unauthorised fuel" for use within a...
  • Page 5: Installation Instructions

    Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 5 Installation Instructions Location of the unit Hearth Requirements The appliance must stand on a level Clearances to non- fireproof hearth with a minimum thickness of 12mm. The hearth combustible materials temperature created by this stove is There is a recommended minimum below 100˚C.
  • Page 6 Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 6 Assembly of the unit This appliance is equipped with a pre-fitted manufacturers smoke exempt stop. Under no circumstances should it be tampered with or removed unless expressly authorised by a competent person and the appliance is not installed in a smoke exempt area. If the appliance is to be installed in a non smoke exempt area you can remove the restricting screw on the secondary air control (on right hand side under the ash lip) to allow full movement of the secondary air slider.
  • Page 7: Operating Your Stove

    Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 7 Operating your stove Please note that during the first firing, Prohibited Fuels we recommend a small fire is lit and that you slowly increase the Green wood: i.e wood which is less than 2 years old with a temperature to enable the various moisture content of above 20% parts to expand normally.
  • Page 8 Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 8 Operating your stove down and pull outwards to increase the burn rate. • Care should be taken to ensure that the logs are not placed higher than the log guard allows. Instructions for use with smokeless fuel •...
  • Page 9 Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 9 Operating your stove Re-fueling Fuel overloading Never overload the stove - it will work When refueling the stove always refuel very well with two medium sized logs. onto a bed of hot embers, fully open The amount of fuel specified in this the secondary and primary air controls manual should not be exceeded,...
  • Page 10: Troubleshooting

    Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 10 Troubleshooting Problem Probable Cause Action Recommend Fire difficult to • Green wood / wet wood Use hardwood logs with a maximum start / goes out moisture content of 20% • Logs are too large Use kindling and small logs to start the fire and once established use split logs •...
  • Page 11: Commissioning Check List

    Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 11 To remove the internal vermiculite baffle: second side brick in the same manner, Firstly remove the front fuel retaining the vermiculite lower baffle can now be bars. Remove the fuel retaining bar removed by lowering the front edge and bracket bolts and brackets.
  • Page 12: Parts Information

    Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 12 Parts Information...
  • Page 13 Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 13 Diagram No. Part No. Description Quantity Required Door Handle 5612-273 Door Retaining Bracket 5411-128 Door Handle Locking Rod 5035-405A Locking Rod Grub Screw GRUBSCREW Cast Iron Door 4490-1385A Door Locking Plate(Not Shown) 5011-406A Glass Clip 6612-219...
  • Page 14: Warranty Information

    Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:46 Page 14 Warranty Information With the aim of constantly The guarantee is for a period of improving our products, all 10 years on the appliance body modifications considered from the date of purchase. necessary may be made The following components are without notice.
  • Page 15: Warranty Claim Form

    Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:46 Page 15 Warranty Claim Form Customer Name: Customer Address: Postcode Daytime Tel: Mobile Tel: Model Name: Model Number: Serial Number: Date of purchase: Date of installation: Installer’s Name and address: Installer’s Registration Number: Building Control Certificate Number: (if not installed by a registered competent installer) Dealer Name and address: In the unlikely event of a warranty claim, please return the above claim form to:...
  • Page 16 Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:46 Page 16 ACR Heat Products Limited, Unit 1, Weston Works, Weston Lane, Tyseley Birmingham B11 3RP, England. • Tel: 0121 706 8266 • Fax: 0121 706 9182 • E-mail: enquiries@acrheatproducts.co.uk • www.acrheatproducts.co.uk...

This manual is also suitable for:

Mal2cl

Table of Contents