Summary of Contents for ACR STOVES Wychwood WYC1WB
Page 1
Elmdale Wychwood Woodburning Stove • Model FB5BK To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove Woodburning Stove Model • WYC1WB WOOD BURNER SMOKE EXEMPT SMOKE EXEMPT AIRWASH AIRWASH SYSTEM SYSTEM YEAR YEAR DIRECT AIR...
Page 2
Thank you for purchasing an ACR Heat Products stove To be retained by the user for future reference...
Page 3
IMPORTANT INFORMATION To ensure that you gain the most from your purchase, please take a few minutes to read through this manual before lighting the appliance for the first time. Since April 2002 only registered competent installers can install solid fuel appliances. Installations carried out by non-registered installers must be inspected by local authority building control.
Page 4
Wychwood Speci cations Nominal heat output 5 kW Chimney draft required 12Pa min Start up 525 mm 555 mm 347 mm 90 Kg e r i N/A*** Flue Mass Gas Flow 4.1 g/s CO @ 13% O 0.12 % Mean Flue Gas Temperature 245 C c i f 82.2 %...
The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities and Rural A airs under Section 16 of the Environmental Better regulation Act may declare the whole or part of the (Northern Ireland) 2016. district of the authority to be a smoke control area.
Installation Instructions Location of the unit Hearth Requirements Clearances to non- The appliance must stand on a level combustible materials reproof hearth with a minimum There is a recommended minimum thickness of 12mm. The hearth clearance of 150mm at each side of the temperature created by this stove is appliance.
Page 7
During the normal operation of your Acr stove, the refractory panels will experience heating and cooling. Sometimes minor hairline cracks can occur. All ACR stoves have a steel or cast iron structure behind the panels and therefore even if the cracks get larger, the stove will still operate safely.
Page 8
Assembly of the unit This appliance is equipped with a pre- tted manufacturers smoke exempt stop. Under no circumstances should it be tampered with or removed unless expressly authorised by a competent person and the appliance is not installed in a smoke exempt area. If the appliance is to be installed in a non smoke exempt area you can remove the restricting screw on the secondary air control (on right hand side under the ash lip) to allow full movement of the secondary air slider.
Operating your stove Please note that during the rst ring, Prohibited Fuels Prohibited Fuels we recommend a small re is lit and Green wood : i.e wood which is that you slowly increase the Green wood : i.e wood which is less than 2 years old with a less than 2 years old with a temperature to enable the various...
Operating your stove • Secondary - right • Start up - Boost Air • Tertiary - left Instructions for use with wood • Pull the secondary air slider (on the • When the re is burning ercely, after a right) fully forward and open the maximum of 5 minutes, add more logs start up air slider (in the middle) fully and close the door.
Operating your stove Re-fueling Fuel overloading Never overload the stove - it will work When refueling the stove always refuel very well with two medium sized logs. onto a bed of hot embers , fully open The amount of fuel speci ed in this the secondary and boost air controls manual should not be exceeded, until the new fuel is well alight, before...
Troubleshooting Problem Probable Cause Action Recommend Fire di cult to • Green wood / wet wood Use hardwood logs with a maximum start / goes out moisture content of 20% • Logs are too large Use kindling and small logs to start the re and once established use split logs •...
second side brick in the same manner, the vermiculite lower ba e can now be To remove the internal vermiculite ba e: removed by lowering the front edge and Firstly remove the front fuel retaining bars. rotating the ba e and removing through the front door.
Page 14
Technical Data & Declaration of Performance Manufacturer: ACR HEAT PRODUCTS Ltd. Models: Wychood 5kW Intended Use: Intermittant domestic heating appliance Independently Performance & Safety tested by: Kiwa Gastec, Noti ed Body No: 0558 Model Wychwood Performance Characteristics using Wood fuel 95/90 Appliance weight (packed/unpacked) (Kg) DIN+...
Warranty Information With the aim of constantly consumable items such as glass, door seals, vermiculite panels, improving our products, all ba e plates and ashpan runners. modi cations considered This 10 year warranty is only necessary may be made without applicable when the stove is notice.
Warranty Claim Form In the unlikely event of a warranty claim, please complete the below claim form and return it to your supplying dealer: Customer Name: Customer Address: Postcode: Daytime Tel: Mobile Tel: Model Name: Model Number: Serial Number: Date of purchase: Date of installation: Installer’s Name and address: Installer’s Registration Number:...
Need help?
Do you have a question about the Wychwood WYC1WB and is the answer not in the manual?
Questions and answers