Page 1
Tenbury Multifuel Stove • Model T550MF To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove MULTI FUEL SMOKE EXEMPT AIRWASH SYSTEM YEAR YEAR WARRANTY Serial Number: T550MF 0101 • Version1 date 20/11/17...
Page 2
Important! To ensure that you gain the most from your purchase, please take a few minutes to read through this manual before lighting the appliance for the first time. Before installation, please ensure that the correct model has been supplied. Please make a note of the serial number of your appliance in the space provided on the front cover of this manual as this will be requested if you require technical assistance in the future.
Page 3
T550 Specifications Nominal heat output 5 kW - Wood 5 kW - Smokeless Fuel Chimney draft required 12Pa Height 550 mm (Internal Box) 585 mm (External Trim) Width 550 mm (Internal Box) 620 mm (External Trim) Depth 334 mm (Recessed) 344 mm (External Trim) Weight 75 kg Air Requirement...
Welsh Ministers. located in a designated smoke control • The Tenbury (T550) has area. It is also an offence to acquire an been recommended as "unauthorised fuel" for use within a...
Installation Instructions Important information Metal Parts This appliance may contain sharp metal Before installation and/or use of this edges, take care when installing or appliance please read these instructions servicing this appliance to avoid carefully to ensure that all requirements personal injury.
Minimum Builders 384mm Opening For ease of installation the builders opening may be made slightly larger than the appliance dimensions, please 560mm see diagram opposite. The construction of fireplace recess should be of a suitable non-combustible material such as brick or concrete blockwork, and have a minimum thickness of 200mm to the sides and rear of the appliance, unless it is a back...
Installation into a wooden decorative fireplace If the appliance is to be fitted in conjunction with a combustible fire 600mm surround the minimum clearances must be maintained, please see diagram opposite (150mm to the sides and 600mm above) these dimensions should 150mm 150mm be adhered to from any point of the...
Installation of the unit Remove the 4 x 10mm bolts located above the baffle. The appliance is supplied pre- Remove the 2 x 10mm bolts located assembled with the flue spigot in the on the left and right half way up top exit position and the Smoke Exempt between the outer convection box stop in place.
mild weather with smokeless fuel. Under Prohibited Fuels certain weather circumstances e.g. fog Green wood: i.e wood which is less the chimney will not draw sufficiently than 2 years old with a moisture content and could cause asphyxiation. Either of above 20% await better weather conditions or burn wood only.
• Open the secondary air slider to the Fuel overloading left hand side of the door, and open Never overload the stove - it will work the primary air slider to the right hand side of the door by fully pushing the very well with two medium sized logs.
Sometimes minor hairline cracks can not intended for emptying hot ashes, occur. All ACR stoves have a steel or never leave hot ashes inside the cast iron structure behind the panels property, always dispose of the hot and therefore even if the cracks get ashes safely outdoors.
Commissioning Check List Please tick boxes when each procedure is completed Ensure the serial number has been recorded on the front of this manual for any future use Ensure the door seals are in good condition and that the glass is secured correctly in the door (do not over tighten the glass as this will prohibit its expansion and could cause the glass to crack) Ensure that all internal components are fitted correctly (these may have shifted in...
Parts Information Diagram No. Part No. Description LD/T/550 Four sided trim attachment TB2-07-00-00 Three sided trim TB-03-10-00 Handle TB2-03-00-00 Door (no rope or Glass) S/4/460X380 Glass TB-03-08-00 Glass clip (four required) 07BL6757-08-00-00 Multifuel cast iron grate TB2-04-00-00 Log guard TB2-05-00-00 Ashpan TB2-02-11-04 Primary air control slider...
Warranty Information With the aim of constantly and glass, ashpan runners, improving our products, all painted/enamel finishes. This 10 modifications considered year warranty is only applicable necessary may be made without when the stove is purchased from notice. one of our recommended retailers. This manual is correct at time of If a stove from any of our brands is printing.
Warranty Claim Form In the unlikely event of a warranty claim, please complete the below claim form and return it to your supplying dealer: Customer Name: Customer Address: Postcode: Daytime Tel: Mobile Tel: Model Name: Model Number: Serial Number: Date of purchase: Date of installation: Installer’s Name and address: Installer’s Registration Number:...
Need help?
Do you have a question about the Tenbury and is the answer not in the manual?