Phenix Technologies KVM100 Manual

Ac/ dc kilovoltmeter

Advertisement

JSH
SEPTEMBER 7, 2011
Rev 2/19/2015 nab
AC/ DC KILOVOLTMETER
MODEL NO. KVM100 / KVM 200
Version 2.2
Phenix Technologies, Inc.
75 Speicher Drive
Accident, Maryland 21520
Copyright © Phenix Technologies, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KVM100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Phenix Technologies KVM100

  • Page 1 AC/ DC KILOVOLTMETER MODEL NO. KVM100 / KVM 200 Version 2.2 Phenix Technologies, Inc. 75 Speicher Drive Accident, Maryland 21520 Copyright © Phenix Technologies, Inc. SEPTEMBER 7, 2011 Rev 2/19/2015 nab...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Description Section Number DANGER / GENERAL SAFETY PRECAUTIONS TECHNICAL SPECIFICATIONS UNCRATING/MECHANICAL SET-UP ELECTRICAL SET-UP / OPERATIONAL NOTES OPERATING INSTRUCTIONS CALIBRATION MECHANICAL MAINTENANCE STORAGE OF EQUIPMENT TROUBLESHOOTING PARTS LISTS RECOMMENDED SPARE PARTS PARTS ORDERING INFORMATION RETURNED MATERIAL CIRCUIT DIAGRAM SYMBOLS ELECTRICAL SCHEMATICS CUSTOMER COMMENTS / SUGGESTIONS...
  • Page 3: Danger / General Safety Precautions

     DO NOT operate damaged equipment. Remove power, and do not use the equipment until safe operation can be verified by service-trained personnel. Phenix Technologies, Inc. assumes no liability for unsafe or improper use of test equipment.
  • Page 4: Technical Specifications

    SECTION 2: TECHNICAL SPECIFICATIONS AC/DC KILOVOLTMETER KVM100 / KVM 200 KVM100 DIVIDER KVM 200 DIVIDER HIGH VOLTAGE AC INPUT: 100kVAC maximum 200 KVAC maximum HIGH VOLTAGE DC INPUT: 100kVDC maximum 200 KVDC maximum HIGH VOLTAGE PK INPUT: 142kV PEAK (AC) 200 KV peak max.
  • Page 5 DIMENSIONS: KVM 100 KVM 200 30 ½” H X 9 ½” W X 91/2” D 43 ½“ H X 9 ½” W X 9 ½” D 1105” H X 241 mm W X 241 mm D 775mm H X 241 mm W X 241 mm D * WEIGHT: 30.5 LBS.
  • Page 6: Uncrating/Mechanical Set-Up

    Perform a visual inspection to determine if the unit was damaged in shipment. If there are any signs of physical damage such as dents, scratches, or oil leaks, contact the Service Department at Phenix Technologies before proceeding. Read and understand all setup and operating instructions before use of the unit. Failure...
  • Page 7: Electrical Set-Up / Operational Notes

    SECTION 4: ELECTRICAL SET-UP / OPERATIONAL NOTES WARNING! THIS UNIT SHOULD ONLY BE OPERATED BY PERSONS KNOWLEDGEABLE OF HIGH VOLTAGE TESTING AND SAFETY PROCEDURES. IMPROPER OPERATION MAY RESULT IN INJURY OR DEATH. ENSURE THAT UNIT TO BE TESTED IS DE-ENERGIZED AND DISCHARGED! ENSURE THAT WORKING ENVIRONMENT IS SAFE AND FREE OF HAZARDS.
  • Page 8 ELECTRICAL SET-UP / OPERATIONAL NOTES                      PHENIX  TECHNOLOGIES    1. CONTROL POWER SWITCH: Depressing this switch will turn on or turn off the control power of the KVM.
  • Page 9: Operating Instructions

    SECTION 5: OPERATING INSTRUCTIONS WARNING THIS UNIT SHOULD ONLY BE OPERATED BY PERSONS KNOWLEDGEABLE OF HIGH VOLTAGE TESTING AND SAFETY PROCEDURES. IMPROPER OPERATION MAY RESULT IN INJURY OR DEATH. 1. DIVIDER WITH METER MODULE OPERATION  Make sure connections have been made as described in “Set-Up” section. ...
  • Page 10 OPERATING INSTRUCTIONS 2. STAND ALONE DIVIDER OPERATION  Make sure connections have been made as described in “Set-Up” section, except that the meter module will not be used or connected.  Connect a Voltmeter to the BNC output on the base of the divider with the 25’ coaxial cable. NOTE: The divider has a 10,000 to 1 ratio.
  • Page 11: Calibration

    SECTION 6: CALIBRATION It is recommended that calibration be performed on a yearly basis. CAUTION: CALIBRATION SHOULD ONLY BE DONE BY PERSONS FAMILIAR WITH HIGH VOLTAGE TESTING AND SAFETY PROCEDURES! CALIBRATION PROCEDURES Due to the complexity and the standards required to calibrate this instrument, Phenix Technologies does not recommend customer calibration.
  • Page 12: Mechanical Maintenance

    Also inspect all fabrication joints for oil leakage. If a leak is found, consult the Service Department at Phenix Technologies.
  • Page 13: Storage Of Equipment

    SECTION 8: STORAGE OF EQUIPMENT If the equipment will be stored for a prolonged period, the following precautions are recommended.  The equipment should be covered and kept in a warm, dry environment (95% maximum humidity, 5 to 50 degrees C). ...
  • Page 14: Troubleshooting

    SECTION 9: TROUBLESHOOTING METERING MODULE  Unit will not turn on: Battery may be discharged. Recharge battery  Unit blanked out during testing because of transient discharge occurrence and won’t come back on by cycling the power switch: Carefully remove front panel, and unplug the battery pack for approximately 30 seconds, then retry power switch.
  • Page 15 10-1 SECTION 10: KVM100/200 PARTS LIST QTY. ITEM PART # DESCRIPTION METERING MODULE PWR CORD 1077167 18/3 9'10" STRT MOD PWR CORD 1151201 25 PIN D-SUBMIN CONN. (FEMALE) W/SOLDER CUP 1151210 FA920 FEMALE SCREWLOCK BATTERY 1590008 BATTERY BOSS BATTERY PACK...
  • Page 16: Recommended Spare Parts

    11-1 SECTION 11: RECOMMENDED SPARE PARTS Phenix Technologies recommends that the customer purchase and stock the following parts for normal maintenance of the unit. The recommended quantity should be sufficient to support the unit during normal operation. If the unit will be operated at an isolated site for an extended period or will be subjected to unusual stresses, a larger quantity of parts should be stocked as spares.
  • Page 17: Parts Ordering Information

    When your purchase order is received at our office, a representative of Phenix Technologies will contact you to confirm the current price of the part being ordered. If a part you order has been replaced with a new or improved part, an Applications Engineer will contact you concerning any change in part number.
  • Page 18: Returned Material

    Serial Number Reason for Return Cause of Defect If Phenix Technologies, Inc. deems return of the part appropriate; it will then issue an "Authorization for Return." If return is not deemed advisable, other inspection arrangements will be made. NOTE: Material received at this plant without the proper authorization shall be held as "Customer's Property"...
  • Page 19: Circuit Diagram Symbols

    14-1 SECTION 14: CIRCUIT DIAGRAM SYMBOLS CIRCUIT DIAGRAM SYMBOLS SYMBOLES POUR SCHEMA DE CIRCUIT SYMBOLE ZU SCHEMA SYMBOL DESCRIPTION DESCRIPTION BEMENKUNG Amplifier Unite d'amplificateur Verstarker ARSR Surge Arrestor Parafoudre Ueberspannungsableiter Capacitor Condensateur Kondensator BSHG Bushing Tranversee Durchfuehoung Electrolytic Capacitor Condensateur electrol Eleckrolytik kondensator Fuse Fusible...
  • Page 20 15-1 SECTION 15: SCHEMATICS AND DRAWINGS Drawing Number Description 1. 7916002 KVM100/200 SCHEMATIC...
  • Page 21: Customer Comments / Suggestions

    15-1 SECTION 15: CUSTOMER COMMENTS/SUGGESTIONS Phenix Technologies made significant efforts to ensure that the materials in this Operator’s Manual are correct. If there are concerns or comments as you have used this information, Phenix Technologies appreciates any feedback. Unit Serial Number:...

This manual is also suitable for:

Kvm200

Table of Contents