Phenix Technologies KVM50A Manual

Ac/ dc kilovoltmeter

Advertisement

Quick Links

DMC
2/2020
Rev New
AC/ DC KILOVOLTMETER
MODEL NO. KVM50A
SERIAL NUMBER
Phenix Technologies, Inc.
75 Speicher Drive
Accident, Maryland 21520
Copyright © Phenix Technologies, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KVM50A and is the answer not in the manual?

Questions and answers

Summary of Contents for Phenix Technologies KVM50A

  • Page 1 AC/ DC KILOVOLTMETER MODEL NO. KVM50A SERIAL NUMBER Phenix Technologies, Inc. 75 Speicher Drive Accident, Maryland 21520 Copyright © Phenix Technologies, Inc. 2/2020 Rev New...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Description Section Number DANGER / GENERAL SAFETY PRECAUTIONS TECHNICAL SPECIFICATIONS UNCRATING/MECHANICAL SET-UP ELECTRICAL SET-UP / OPERATIONAL NOTES OPERATING INSTRUCTIONS CALIBRATION MECHANICAL MAINTENANCE STORAGE OF EQUIPMENT TROUBLESHOOTING PARTS LISTS RECOMMENDED SPARE PARTS PARTS ORDERING INFORMATION RETURNED MATERIAL CIRCUIT DIAGRAM SYMBOLS ELECTRICAL SCHEMATICS CUSTOMER COMMENTS / SUGGESTIONS...
  • Page 3 DANGER / WARNINGS Complete Grounding of this unit is necessary for the safe operation of this equipment. Disconnect inputs before ungrounding this equipment...
  • Page 4: Danger / General Safety Precautions

    • DO NOT operate damaged equipment. Remove power, and do not use the equipment until safe operation can be verified by service-trained personnel. Phenix Technologies, Inc. assumes no liability for unsafe or improper use of test equipment.
  • Page 5: Technical Specifications

    SECTION 2: TECHNICAL SPECIFICATIONS AC/DC KILOVOLTMETERKVM50E KVM50 DIVIDER HIGH VOLTAGE AC INPUT: 50kVAC maximum HIGH VOLTAGE DC INPUT: 50kVDC maximum HIGH VOLTAGE PK INPUT: 74kV PEAK (AC) 300M  DIVIDER RESISTANCE: ≤ 15 pF DIVIDER CAPACITANCE: DIVIDER RATIO: 10,000:1 INSTRUMENTATION: AC / BATTERY POWERED POWER ADAPTOR: INPUT: 85-264 Volts AC, 0.6 AMPS, 47-63 HZ...
  • Page 6 DIMENSIONS: 30 ½” H X 9 ½” W X 91/2” D 775mm H X 241 mm W X 241 mm D WEIGHT: 30.5 LBS. 13.8 kg * WEIGHT INCLUDES ALL CABLES...
  • Page 7: Uncrating/Mechanical Set-Up

    Perform a visual inspection to determine if the unit was damaged in shipment. If there are any signs of physical damage such as dents, scratches, or oil leaks, contact the Service Department at Phenix Technologies before proceeding. Read and understand all setup and operating instructions before use of the unit. Failure...
  • Page 8: Electrical Set-Up / Operational Notes

    SECTION 4: ELECTRICAL SET-UP / OPERATIONAL NOTES WARNING! THIS UNIT SHOULD ONLY BE OPERATED BY PERSONS KNOWLEDGEABLE OF HIGH VOLTAGE TESTING AND SAFETY PROCEDURES. IMPROPER OPERATION MAY RESULT IN INJURY OR DEATH. ENSURE THAT UNIT TO BE TESTED IS DE-ENERGIZED AND DISCHARGED! ENSURE THAT WORKING ENVIRONMENT IS SAFE AND FREE OF HAZARDS.
  • Page 9 ELECTRICAL SET-UP / OPERATIONAL NOTES 1. CONTROL POWER SWITCH: Button will turn on or turn off control power of KVM. 2. BATTERY STATUS: Press button to indicate charge level of battery. 3. INPUT / CHARGING LAMP: Illuminates when external input / charging power is present. 4.
  • Page 10: Operating Instructions

    SECTION 5: OPERATING INSTRUCTIONS WARNING THIS UNIT SHOULD ONLY BE OPERATED BY PERSONS KNOWLEDGEABLE OF HIGH VOLTAGE TESTING AND SAFETY PROCEDURES. IMPROPER OPERATION MAY RESULT IN INJURY OR DEATH. 1. DIVIDER WITH METER MODULE OPERATION • Make sure connections have been made as described in “Set-Up” section. •...
  • Page 11 OPERATING INSTRUCTIONS 2. STAND ALONE DIVIDER OPERATION • Make sure connections have been made as described in “Set-Up” section, except that the meter module will not be used or connected. • Connect a Voltmeter to the BNC output on the base of the divider with the 25’ coaxial cable. NOTE: The divider has a 10,000 to 1 ratio.
  • Page 12: Calibration

    CAUTION: CALIBRATION SHOULD ONLY BE DONE BY PERSONS FAMILIAR WITH HIGH VOLTAGE TESTING AND SAFETY PROCEDURES! CALIBRATION PROCEDURES Due to the complexity and the standards required to calibrate this instrument, Phenix Technologies does not recommend customer calibration. For further information please contact our Service Department.
  • Page 13: Mechanical Maintenance

    Also inspect all fabrication joints for oil leakage. If a leak is found, consult the Service Department at Phenix Technologies.
  • Page 14: Storage Of Equipment

    SECTION 8: STORAGE OF EQUIPMENT If the equipment will be stored for a prolonged period, the following precautions are recommended. • The equipment should be covered and kept in a warm, dry environment (95% maximum humidity, 5 to 50 degrees C). •...
  • Page 15: Troubleshooting

    SECTION 9: TROUBLESHOOTING METERING MODULE • Unit will not turn on: Battery may be discharged. Recharge battery • Unit blanked out during testing because of transient discharge occurrence and won’t come back on by cycling the power switch: Carefully remove front panel, and unplug the battery pack for approximately 30 seconds, then retry power switch.
  • Page 16 10-1 SECTION 10: KVM50EA PARTS LIST QTY. ITEM PART # DESCRIPTION METERING MODULE BATTERY BATTERY PACK 1153068 31-010 BNC PNL MT ISOL CABLE 30080007 10FT 10 GA GND CABLE CASE-GND 1351103 BINDING POST (GREEN) 459-104 DC JK DC POWER JACK- 2.1MM 4-1/2 DIGIT LCD PANEL METER PLUG 1152210...
  • Page 17: Recommended Spare Parts

    11-1 SECTION 11: RECOMMENDED SPARE PARTS Phenix Technologies recommends that the customer purchase and stock the following parts for normal maintenance of the unit. The recommended quantity should be sufficient to support the unit during normal operation. If the unit will be operated at an isolated site for an extended period or will be subjected to unusual stresses, a larger quantity of parts should be stocked as spares.
  • Page 18: Parts Ordering Information

    When your purchase order is received at our office, a representative of Phenix Technologies will contact you to confirm the current price of the part being ordered. If a part you order has been replaced with a new or improved part, an Applications Engineer will contact you concerning any change in part number.
  • Page 19: Returned Material

    Serial Number Reason for Return Cause of Defect If Phenix Technologies, Inc. deems return of the part appropriate; it will then issue an "Authorization for Return." If return is not deemed advisable, other inspection arrangements will be made. NOTE: Material received at this plant without the proper authorization shall be held as "Customer's Property"...
  • Page 20: Circuit Diagram Symbols

    14-1 SECTION 14: CIRCUIT DIAGRAM SYMBOLS CIRCUIT DIAGRAM SYMBOLS SYMBOLES POUR SCHEMA DE CIRCUIT SYMBOLE ZU SCHEMA SYMBOL DESCRIPTION DESCRIPTION BEMENKUNG Amplifier Unite d'amplificateur Verstarker ARSR Surge Arrestor Parafoudre Ueberspannungsableiter Capacitor Condensateur Kondensator BSHG Bushing Tranversee Durchfuehoung Electrolytic Capacitor Condensateur electrol Eleckrolytik kondensator Fuse Fusible...
  • Page 21 15-1 SECTION 15: SCHEMATICS AND DRAWINGS Drawing Number Description 1. 7916005 KVM CONTROLS SCHEMATIC 2. 796-XX-XXXX KVM50EA SCHEMATIC...
  • Page 23: Customer Comments / Suggestions

    16-1 SECTION 16: CUSTOMER COMMENTS/SUGGESTIONS Phenix Technologies made significant efforts to ensure that the materials in this Operator’s Manual are correct. If there are concerns or comments as you have used this information, Phenix Technologies appreciates any feedback. Unit Serial Number: 18-2777...

Table of Contents