Siemens SITRANS P210 Compact Operating Instructions page 26

Pressure transmitter
Table of Contents

Advertisement

Technical specifications
8.1 General technical specifications
Measuring accuracy
Rated conditions
Ambient temperature
Storage temperature
Degree of protection (according to EN 60529)
Electromagnetic compatibility
Mechanical construction
Weight
Process connections
Electrical connections
Material of the wetted parts
Non-wetted parts material
26
Influence of vibration (per IEC 60068-2-6)
Effect of auxiliary power supply
Height
Relative humidity
Measuring cell
Process connection
Sealing material
Viton (FPM)
Neoprene (CR)
Perbunan (NBR)
EPDM
Enclosure
0.005%/g to 500 Hz in all directions
0.005%/V
-25 ... +85 °C (-13 ... +185 °F)
Max. 2 000 m above mean sea level
Use a suitable power supply at an altitude of more
than 2 000 m above mean sea level.
0 ... 100%
‑50 ... +100 °C (-58 ... +212 °F)
IP65 with plug according to EN 175301-803-A
IP67 with M12 plug
IP67 with cable
IP67 with fast-fit cable gland
In accordance with EN 61326-1
In accordance with EN 61326-2-3
In accordance with NAMUR NE21, only for ATEX
devices and with a maximum measurement de‐
viation of ≤1%
Approx. 0.090 kg (0.198 lb)
Dimension drawings (Page 29)
Plug in accordance with EN 175301-803-A shape A with cable
entry M16x1.5 or ½-14NPT or Pg 11
M12 plug
2- or 3-wire (0.5 mm
) cable (∅ 5.4 mm)
2
Fast-fit cable gland
Stainless steel, mat. no. 1.4435
Stainless steel, Mat. No. 1.4404 (SST 316 L)
15th digit in the order number
A
B
C
D
Stainless steel, Mat. No. 1.4404 (SST 316 L)
Compact Operating Instructions, 09/2020, A5E03304388-AA
Medium temperature
-15 ... +125 °C (+5 ... +257° F)
-35 ... +100 °C < 100 bar (‑31 ...
+212 °F; < 1 450 psi)
-20 ... +100 °C (‑4 ... +212 F)
-40 ... +125 °C < 100 bar (‑40 ...
+257 °F; < 1 450 psi), can be used
for drinking water
SITRANS P210

Advertisement

Table of Contents
loading

Table of Contents