Page 1
Edition:Version 2.1 in 2023 Copyright, subject to change without notice. EC6000 Series AC Drive Quick Guide V2.1 ZHEJIANG EACN ELECTRONIC TECHNOLOGY CO.,LTD Address:No.1 Jinhe Road, Qinshan Street, Haiyan County, Jiaxing City, Zhejiang Province Service line: 86-400-166-0573 Website: www.eacn.cn E-mail: overseas@eacon.cc...
1.Preface V1.0 TABLE OF CONTENTS Thank you for using the EC6000 series high-performance current vector control AC drive. Please carefully read this manual before the installation in order to ensure the correct 1 Preface installation and operation of the AC drive, give full play to its superior performance, and ensure 2 Description of AC drive safety.
43 represents three-phase 400V Capacity specification of AC drive 165.0 0011G represents 11kW constant torque 185.0 0015P represents 15kW variable torque 210.0 Serial number: EC6000 250.0 Abbreviation of “EACON” 307.0 380.0 2.3 Description of Serial number 450.0 480.0 520.0 Sequence number 605.0 Years 670.0...
T e c h n i c a l S p e c i f i c a t i o n s EC6000 EC6000 M e c h a n i c a l d i m e n s i o n o f A C d r i v e 4.Mechanical dimension of AC drive I t e m S p e c i ficat i o n s...
EC6000 M e c h a n i c a l d i m e n s i o n o f A C d r i v e EC6000 M a i n C i r c u i t C o n n e c t i o n F u n c t i o n s 220V Class 220kW 250kW...
Page 7
Type Function Description Terminal Name Analog input 1. Input voltage range: DC 0V~10V AI1-GND 2. Impedance: 22kΩ termianl 1 Analog Analog input AI2-GND 1. Input range: DC 0V~10V/4mA–20mA,decided by selection input termianl 2 of P5-00. Analog input 2. Impedance: 22kΩ(voltage input),500Ω(current input) AI3-GND termianl 3 S1-COM...
O p e r a t i o n a n d d i s p l a y EC6000 EC6000 F a u l t s a n d s o l u t i o n s 7.3 Description of Keys on the LED operation panel 1: The output circuit is grounded or short circuited.
Page 9
EC6000 F a u l t s a n d s o l u t i o n s EC6000 F a u l t s a n d s o l u t i o n s 1: Handle based on over-voltage. AC drive 1: Overvoltage exists.
EC6000 F a u l t s a n d s o l u t i o n s EC6000 F u n c t i o n C o d e T a b l e 9.Function Code Table Digital setting of P0 Standard Parameter group...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e P1 Motor parameters BIT1:A/B phase sequence of ABZ incremental Function encoder Setting Range...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e P4 Input Terminals functio n Voltage digital P3-16 setting for...
Page 14
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e P4-14 Reserved 040EH BIT0: S1 terminal 0: Effective closing 1: Effective opening P4-15...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e AI3 input voltage 30:Module temperature Reached Y7 terminal lower limit 31:Fan running...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e BIT0: Panel digital potentiometer setting Accumulative power consumption Read-only...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e P9 Fault and pr otection parameters Frequency detection P8-17 50.00Hz...
Page 19
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e AC drive status 15 -- ERROR_EXTERNAL EQUIPMENT P9-18 Same as P9-10 Read-only...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e Over-speed BIT2: Power on time arrival (Err29) action P9-41 0.0~60.0s 1.0s...
Page 21
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e Differential PA-10 0.000~10.000s 0.000s 0A0AH time Td1 5: Communication feedback...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e 0: Fault BIT0: Circulation mode Solution of 1: Continue to operate within the allowable 0: Stop after the AC drive runs one cycle...
Page 24
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e Running Running direction and direction and acceleration/ acceleration/...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e Preset frequency BIT 2:Main and frequency source selection PD-48 0.00~650.00s 0.00s...
EC6000 F u n c t i o n C o d e T a b l e EC6000 F u n c t i o n C o d e T a b l e Industry frequency 4: Frequency transform pump circulating, has 0.00~maximum frequency A1-18 50.00Hz...
Application mode Rated voltage U-35 2133H 1. EC6000 series AC drive has a "single master and multi slave" control of AC drive network connected to RS485 bus. When the master uses the broadcast command Rated current (slave address is 0), the slave does not answer.
Page 28
EC6000 EC6000 R S 4 8 5 c o m m u n i c a t i o n p r o t o c o l R S 4 8 5 c o m m u n i c a t i o n p r o t o c o l In the RTU mode, the new one frame use at least 3.5 pieces bytes transmit Data address 2102H high position time stop interval as start.
Page 29
Sub machine address relate function parameter setting of AC drive, etc. Order code (1) EC6000 series function parameter address description rules Check the code high position Use the function parameter serial number of AC drive as the register add- Check the code low position ress, divided into two parts at high bits and low bits.
Page 30
EC6000 EC6000 R S 4 8 5 c o m m u n i c a t i o n p r o t o c o l R S 4 8 5 c o m m u n i c a t i o n p r o t o c o l Control order Address Motor control mode...
User Name User Address User Contact Specification Number Di stributor Date of Contacts delivery ZHE JIANG EACN ELECTRONIC TECHNOLOGY CO.,LTD. Address:No.1 Jinhe Road, Qinshan Street, Haiyan County, Jiaxing City, Zhejiang Province . Website: www.eacon.cn E-mail: overseas@eacon.cc - 6 0 -...