FLUSH INSTALLATION INSTRUCTIONS
STEP 1 - CABINET OR WALL OPENING
The opening in the wall or cabinet must be within the following
dimensions:
OPENING
SKM427F9HS
3
A
24
/
" (628.7 mm)
4
1
Width (B)
27
/
" (689 mm)
8
7
Height (C)
22
/
" (569.9 mm)
16
3
D
1
/
" (30.2 mm)
16
1
E
3
/
" (82 mm)
4
1
F
1
/
" (38.8 mm)
2
G
4" (101.6 mm)
Minimum
20" (508 mm)
Depth (I)
Outlet should NOT be in the shaded area H as indicated in
Figure 1.
Top View
A
B
Front View
D
D
Shelf
E
Bottom of flush cutout
NOTES
Dimension C above will result in 1
above and below the trim to allow for necessary intake and
exhaust air flow to ensure appliance does not overheat. Do
not reduce this spacing as doing so will void the warranty
for any issues resulting from a lack of airflow.
SKM430F9HS
3
24
/
" (628.7 mm)
4
1
30
/
" (768.4 mm)
4
7
22
/
" (569.9 mm)
16
11
2
/
" (67.5 mm)
16
1
3
/
" (82 mm)
4
1
1
/
" (38.8 mm)
2
4" (101.6 mm)
20" (508 mm)
Mounting
cleat
Shelf
F
Cabinet
face
H
C
B
Figure 1
" (31.8 mm) spaces
1
4
NOTES
• Allow minimum 3" (76 mm) wood gap between the
microwave oven cutout and the appliance cutout below
the microwave oven. See Figure 2.
• The floor of the opening should be constructed of plywood
strong enough to support the weight of the oven and floor
load (about 100 lb/45 kg). The floor should be level and
90˚ with the face of the cabinet for proper installation and
operation of the oven. Check the local building code that
may require that the opening be enclosed with sides,
ceiling and rear partition. The proper functioning of the
oven does not require the enclosure.
I
4
Microwave cutout
3" Min.
Wall oven cutout
Figure 2