58300000181895 ARA EN A
The following components are located in the front area of the top
plenum, and it may be possible to service them through the service
panel without removing the top front and/or rear housing cover(s)...
Control module (relay board)
Daughter board (double ovens only)
Terminal block
5.4.1

Top Access: Non-combination Models

To reach the service panel, remove the screws securing the side trim
to the cabinetry, and slide the oven out of the cutout ~8-9 inches.
For unrestricted access to the top front plenum area, remove the
screws securing the side trim pieces to the cabinetry, then slide the
oven out of the cutout approximately ~16 inches, and remove the top
front housing cover completely.
5.4.2

Top Access: Combination Models

To reach the service panel on an HBLP751UCC or HSLP751UCC
oven, follow the steps below...
1. Remove the screws securing the right
and left side trim pieces to the
cabinetry.
2. Carefully slide the combination oven
out of the cutout ~8-9 inches.
3. Remove the locking screw from
the right and left service slides (see
Figure 7).
4. Carefully slide the microwave or
steam oven to the rear ~7 inches; the
service access panel will be
accessible.
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
1 – RH service slide
2 – RH locking screw
2
Figure 7 Location of RH rail locking screw on combo oven
1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614
JUNE 2014
Service Manual for Bosch Benchmark Series Built-in Wall Ovens
CAUTION
When servicing the standard wall oven component of an
HBLP751UC or HSLP751UC combination oven, only the top front
service access panel will be accessible without removing the
microwave oven or steam oven.
If additional access to the top area of the oven is required, the
microwave or steam oven component must be removed. To safely
remove and reinstall the microwave or speed oven, two people
are required.
If unrestricted access to the top plenum area of the traditional wall
oven, the speed microwave or steam convection oven will need to be
removed.
Note that the length of the conduit/feeder wires which connect the
microwave or steam oven to the oven beneath it are ~5' long. If there
is a work table nearby, it may not be necessary to disconnect the
feeder wires from the terminal block located in the oven-mounted
junction box on the top of the oven housing.
1
Figure 8 Top view of wall oven and microwave conduit/feeder wire connection in junction box.