SECTION 5
SELECTING THE LOCATION
WARNINGS:
All fire pits, match lit kits, spark ignition, safety pilot and Electronic Ignition Components are
designed and intended for outdoor use only.
All fire pits must have a gas shutoff on the outside of the exterior of the fire pit to allow for
emergency shut off and maintenance. DO NOT PLACE ON TOP OF NON-COMBUSTIBLE FLOORING.
Select a location where the fire pit can be attended during operation. Never leave an operating
fire pit unattended or by someone not familiar with its operation or emergency shut off locations.
Both children and adults should be alerted to the hazards of high surface temperatures and
should stay away to avoid burns and clothing ignition.
Young children should be carefully supervised when they are in the area of fire pit.
Clothing or other flammable materials should not be placed on or near fire pit.
Fire pits create very high temperatures - Combustibles must be located far enough away that
there is no risk of ignition.
IMPORTANT:
It is recommended that material such as granite, marble or other dense stone be kept away from
heat and especially flame due to risk of cracking. Manufacturer is not responsible for damage.
CLEARANCE FROM COMBUSTIBLES | UP TO 65K BTUS | SEE SECTION 15
Under Valve Box When Applicable
Sides Surrounding Fire Pit
Overhead Clearance
CLEARANCE FROM COMBUSTIBLES | 66K TO 200K BTUS | SEE SECTION 15
Under Valve Box When Applicable
Sides Surrounding Fire Pit
Overhead Clearance
CLEARANCE FROM COMBUSTIBLES | 201K TO 400K BTUS | SEE SECTION 15
Under Valve Box When Applicable
Sides Surrounding Fire Pit
Overhead Clearance
Select a location with proper drainage.
Choose a location that allows easy access for installation and maintenance of the fire pit.
Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe
distance from the heat and flame.
WARNING:
Venting is required to dissipate heat and any residual fuel. Failure to
provide proper ventilation could result in overheating and or explosion. See Proper
Venting topic in the Enclosure Construction Section.
EXPERT TECHNICAL SUPPORT | MADE IN THE U.S.A. | 701 S. DUPONT AVE. ONTARIO, CA 91761 U.S.A.
2" For Drainage
36" From Structure or Combustibles
Min. 84" Overhead Clearance
2" For Drainage
48" From Structure or Combustibles
NO OVERHEAD CONSTRUCTION
2" For Drainage
48" From Structure or Combustibles
NO OVERHEAD CONSTRUCTION