The Outdoor Plus OPT-BP24SQDSSE110 Installation & Operation Manual

Plug & play to low voltage pans & burners

Advertisement

Quick Links

INSTALLATION & OPERATION MANUAL
PLUG & PLAY TO LOW VOLTAGE
SQUARE DROP-IN PAN &
SQUARE SS BULLET BURNER
OPT-BP24SQDSSE110
DANGER: FIRE OR EXPLOSION HAZARD
If you smell gas:
» Shut off gas to the appliance.
» Extinguish any open flame.
» If odor continues, leave the area immediately.
» After leaving the area, call your gas supplier or fire department.
Failure to follow these instructions could result in fire or explosion, which could cause
property damage , personal injury, or death.
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent,
car or home.
Installation
We suggest that our products be installed by professionals that are
locally licensed by the authority having jurisdiction in gas piping.
Service
We suggest that our products be serviced by a professional certified in
the US by the National Fireplace Institute (NFI) as NFI Gas Specialists.
INSTALLER: Leave this manual with the appliance. | CONSUMER: Retain the manual for future reference.
PANS & BURNERS
ROUND FLAT PAN &
TRIPLE 'S' SS BULLET
OPT-BFP24RSSE110
DANGER: Carbon Monoxide Hazard
PHONE: +1 (909) 460-5579
EMAIL: SUPPORT@THEOUTDOORPLUS.COM
ADDRESS: 701 S DUPONT AVE. ONTARIO, CA 91761 U.S.A.
WEBSITE: THEOUTDOORPLUS.COM
BURNER
RECTANGULAR DROP-IN PAN
& 'H' SS BULLET BURNER
OPT-BP1260RDSSE110

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPT-BP24SQDSSE110 and is the answer not in the manual?

Questions and answers

Summary of Contents for The Outdoor Plus OPT-BP24SQDSSE110

  • Page 1 ROUND FLAT PAN & RECTANGULAR DROP-IN PAN SQUARE SS BULLET BURNER TRIPLE ‘S’ SS BULLET & ‘H’ SS BULLET BURNER BURNER OPT-BP24SQDSSE110 OPT-BP1260RDSSE110 OPT-BFP24RSSE110 DANGER: FIRE OR EXPLOSION HAZARD If you smell gas: » Shut off gas to the appliance.
  • Page 2 SECTION 1 WARNINGS THIS SECTION OUTLINES WARNING ASSOCIATED WITH INSTALLATION, USE, AND OPERATION. This is a Safety Alert Symbol When you see this symbol on the fire pit insert, or in this manual, look for one of the following signal word panels alerting you to the potential for personal injury, death or major property damage.
  • Page 3 SECTION 1 WARNINGS CONT’D. THIS SECTION OUTLINES WARNING ASSOCIATED WITH INSTALLATION, USE, AND OPERATION. * EXCEPT AS AUTHORIZED BY ANSI Z223.1 / NFPA 58 EXPERT TECHNICAL SUPPORT | MADE IN THE U.S.A. | 701 S. DUPONT AVE. ONTARIO, CA 91761 U.S.A.
  • Page 4 Canada by WETT (Wood Energy Technical Training). Installer must follow all instructions carefully to ensure proper performance and safety. ▪ The Outdoor Plus Company, Inc. is not responsible for your actions. ▪ Product is not intended to be a starter for wood or any other combustibles.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS DIRECTORY OF PAGES & SECTIONS SECTION 1 | WARNINGS ......................3 SECTION 2 | IMPORTANT SAFETY INFORMATION ..............5 SECTION 3 | COMPONENTS OVERVIEW .................6 SECTION 4 | OPERATION SEQUENCE ..................8 SECTION 5 | SELECTING THE LOCATION ................9 SECTION 6 | ENCLOSURE CONSTRUCTION .................
  • Page 6: Section 3 | Components Overview

    SECTION 3 COMPONENTS OVERVIEW THIS SECTION OUTLINES THE FEATURES OF THE PLUG & PLAY TO LOW VOLTAGE PANS & BURNERS Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 / NFPA 54, or International Fuel Gas Code. appliance when installed,...
  • Page 7 The Electronic Ignition Valve is designed to automatically close the gas valve and shut down should temperatures exceed 175° Fahrenheit. To keep the unit cool, proper ventilation and a heat shield must be provided. The Outdoor Plus Recommends a Stainless Steel Whistle-Free Flex Hose to eliminate the noise. PILOT ASSEMBLY CONNECTIONS We pre-assemble the pilot on top of the burner pan and in that configuration, the pilot line, thermocouple and igniter lead should be lowered through a hole in the pan prior to connecting to the control box.
  • Page 8: Section 4 | Operation Sequence

    SECTION 4 OPERATION SEQUENCE THIS SECTION DEMONSTRATES THE OPERATION SEQUENCE OF OUR PLUG & PLAY TO LOW VOLTAGE PANS & BURNERS. THEOUTDOORPLUS.COM | +1 (909) 460-5579 | SUPPORT@THEOUTDOORPLUS.COM...
  • Page 9: Section 5 | Selecting The Location

    SECTION 5 SELECTING THE LOCATION THIS SECTION DEMONSTRATES LOCATION REQUIREMENTS & WARNINGS WARNINGS: ▪ All fire pits, match lit kits, spark ignition, safety pilot and Electronic Ignition Components are designed and intended for outdoor use only. ▪ All fire pits must have a gas shutoff on the outside of the exterior of the fire pit to allow for emergency shut off and maintenance.
  • Page 10: Section 6 | Enclosure Construction

    ▪ The Outdoor Plus recommends that the pan lip is recessed on trough (linear). The Outdoor Plus cannot guarantee the lip on all of our products will be perfectly flat and will not warp due to heat.
  • Page 11: Section 7 | Pre-Planning Checklist

    SECTION 7 PRE-PLANNING CHECKLIST THIS SECTION DEMONSTRATES THE PROPER INSTALLATION AND TESTING OF THE Plug & Play to Low Voltage Pans & Burners. TO ENSURE PROPER INSTALLATION PLEASE USE THIS PRE-PLANNING CHECKLIST: ▫ Recommended Tools: ▫ General Plumbing Tools (Pipe Wrench, Crescent Wrench, Pipe Cutters, etc.) ▫...
  • Page 12: Section 8 | Installation Instructions

    SECTION 8 INSTALLATION INSTRUCTIONS THIS SECTION DEMONSTRATES THE PROPER INSTALLATION AND TESTING OF THE PLUG & PLAY TO LOW VOL TAGE PANS & BURNERS STEP 1 | SELECTING A LOCATION ▪ Please see Section 5 on Selecting a location for instructions. STEP 2 | VENTILATION &...
  • Page 13 SECTION 8 INSTALLATION INSTRUCTIONS CONT’D. THIS SECTION DEMONSTRATES THE PROPER INSTALLATION AND TESTING OF THE PLUG & PLAY TO LOW VOL TAGE PANS & BURNERS STEP 7 | OPERATION INSTRUCTIONS ▪ Please see Section 11 on Operation Instructions, this section outlines how to operate your Plug & Play to Low Voltage Pans &...
  • Page 14 SECTION 8 INSTALLATION INSTRUCTIONS CONT’D. THIS SECTION DEMONSTRATES THE PROPER INSTALLATION AND TESTING OF THE PLUG & PLAY TO LOW VOL TAGE PANS & BURNERS Figure 3.1 Ball Figure 3.2 Ball ▪ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 15 SECTION 8 INSTALLATION INSTRUCTIONS CONT’D. THIS SECTION DEMONSTRATES THE PROPER INSTALLATION AND TESTING OF THE PLUG & PLAY TO LOW VOL TAGE PANS & BURNERS You may also cut off the three-prong plug and hardwire the leads into any 110V application you’d like.
  • Page 16 SECTION 8 INSTALLATION INSTRUCTIONS CONT’D. THIS SECTION DEMONSTRATES THE PROPER INSTALLATION AND TESTING OF THE PLUG & PLAY TO LOW VOL TAGE PANS & BURNERS ▪ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 17 SECTION 8 INSTALLATION INSTRUCTIONS CONT’D. THIS SECTION DEMONSTRATES THE PROPER INSTALLATION AND TESTING OF THE PLUG & PLAY TO LOW VOL TAGE PANS & BURNERS NOTE: Propane cylinder NOT included. Make sure to properly locate the gas hose including locating the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage.
  • Page 18: Section 9 | Fire Media Usage

    SECTION 9 FIRE MEDIA USAGE THIS SECTION DEMONSTRATES HOW FIRE MEDIA SHOULD BE INSTALLED & WARNINGS WARNING: Lava Do not use any other material as media in the fire feature other than: rock no smaller than 1/2” average diameter. » DO NOT USE FIRE GLASS »...
  • Page 19 SECTION 9 FIRE MEDIA USAGE THIS SECTION DEMONSTRATES HOW FIRE MEDIA SHOULD BE INSTALLED & WARNINGS MUST READ! BURNING MEDIA INSTALLATION CORRECT INSTALLATION WRONG INSTALLATION �� �� » » ONLY FIRE-RATED MEDIA NO PAN TO HOLD MEDIA » PAN TO HOLD MEDIA »...
  • Page 20: Section 10 | Parts List

    SECTION 10 PARTS LIST THIS SECTION OUTLINES THE LIST OF REPLACEABLE PARTS Ball Valve...
  • Page 21: Section 11 | Operation & Usage

    SECTION 11 OPERATION & USAGE THIS SECTION EXPLAINS HOW TO OPERATE THE FIRE FEATURE. Congratulations on getting your new fire feature installed! Let’s get started with how to operate and use your new Plug & Play to Low Voltage Pans & Burners fire feature! Your fire feature should have one of the following methods to turn on and off the fire feature:...
  • Page 22 SECTION 11 OPERATION & USAGE CONT’D THIS SECTION EXPLAINS HOW TO OPERATE THE FIRE FEATURE. Starting Up Your Electronic Ignition Component ▪ Startup: A few “On/Off” Cycles may be required in order to properly air within the gas lines after electronic ignition valve installation. The Fire Pit will lockout after 10 attempts to light the pilot - If this happens, power OFF then ON to restart.
  • Page 23: Section 12 | Troubleshooting

    SECTION 12 TROUBLESHOOTING THIS SECTION DEMONSTRATES POTENTIAL ISSUES & COUNTERMEASURES TO REPAIR YOUR UNIT SEQUENCE FAULT CHECK RESULT ACTION(S) OPERATION Check for 14V at No or low Make sure transformer is powered. If so, replace Transformer voltage transformer. No Function / No LED Check wiring for continuity, replace if broken.
  • Page 24 SECTION 12 TROUBLESHOOTING CONT’D THIS SECTION DEMONSTRATES POTENTIAL ISSUES & COUNTERMEASURES TO REPAIR YOUR UNIT THE ELECTRONIC IGNITION VALVE IS INSTALLED BUT WHEN TURNED ON NOTHING HAPPENS: The most common cause is an electrical wiring or power issue. Inspect all electrical connections carefully to confirm all wires from the transformer to the fire feature are connected properly.
  • Page 25 SECTION 12 TROUBLESHOOTING CONT’D THIS SECTION DEMONSTRATES POTENTIAL ISSUES & COUNTERMEASURES TO REPAIR YOUR UNIT » CAUTION: Turn off the gas supply before proceeding. » Utilizing clamp on ammeter, clamp the ammeter around one of the wires providing power to the Electronic Ignition Valve. »...
  • Page 26: Section 13 | Maintenance

    (see your local The Outdoor Plus Store propane cylinders outdoors in a well- dealer for details). ventilated area out of reach of children. Disconnected cylinders must have threaded...
  • Page 27 SECTION 13 MAINTENANCE CONT’D THIS SECTION SHOWS YOU HOW TO MAINTAIN AND UPKEEP THE FIRE FEATURE REMOVAL OF DEBRIS ▪ Do NOT perform the maintenance until surfaces of the fire feature are cool to the touch, The Outdoor Plus recommends leaving the fire pit off for at least 1 hour prior to servicing.
  • Page 28: Section 14 | Replacement Parts

    SECTION 14 REPLACEMENT PARTS THIS SECTION SHOWS REPLACEMENT PARTS YOU MAY ORDER TO REPAIR THE COMPONENTS. 24" PILOT IGNITER ASSEMBLY TOP-500PIR MINI & STANDARD CAPACITY UNITS TOP-500PIRHC HIGH CAPACITY UNITS PILOT IGNITER PILOT IGNITER PILOT ORIFICE(S) COVER GLOW PLUG TOP-PIC TOP-PIGP TOP-PI23 | #23 ORIFICE MINI CAPACITY UNITS...
  • Page 29 Min. 68” Overhead Clearence...
  • Page 30: Section 15 | Clearance From Combustibles

    Installation We suggest that our products be installed by professionals that are locally SECTION 15 licensed by the authority having jurisdiction in gas piping. CLEARANCE FROM COMBUSTIBLES THIS SECTION OUTLINES THE CLEARANCE FROM COMBUSTIBLES REQUIREMENTS FOR SAFE OPERATION Service We suggest that our products be serviced by a professional certified in the US by the National Fireplace Institute (NFI) as NFI Gas Speciatlists Clearance for units 66k to 200k BTUs - For Outdoor Use Only Min.
  • Page 31 Installation We suggest that our products be installed by professionals that are locally SECTION 15 licensed by the authority having jurisdiction in gas piping. CLEARANCE FROM COMBUSTIBLES THIS SECTION OUTLINES THE CLEARANCE FROM COMBUSTIBLES REQUIREMENTS FOR SAFE OPERATION Service We suggest that our products be serviced by a professional certified in the US by the National Fireplace Institute (NFI) as NFI Gas Speciatlists Clearance for units 201k to 400k BTUs - For Outdoor Use Only Min.
  • Page 32 Clearance for units 401K BTUs and up - For Outdoor Use Only...
  • Page 33: Section 16 | Warranty Information

    SECTION 16 WARRANTY INFORMATION THIS SECTION OUTLINES THE WARRANTY OFFERED BY THE OUTDOOR PLUS ▪ The Outdoor Plus Company (TOP) warranties its products TOP is not responsible for local codes and will not against manufacturing defects that prevent safe and...

This manual is also suitable for:

Opt-bp1260rdsse110Opt-bfp24rsse110

Table of Contents